Keysight (Agilent) DDA 5005A XXL Disk Drive Analyzer

The Keysight (Agilent) DDA 5005A XXL Disk Drive Analyzer is a specialized instrument for comprehensive testing and analysis of disk drives. It provides in-depth characterization of drive performance, identifying potential issues and ensuring optimal operation. Ideal for manufacturers and repair technicians, this analyzer offers a detailed look into the drive’s functionality.

Model
Keysight / Agilent DDA 5005A
Calibration
Available on request
Price
$4,500
Status
In stock
RFQ ref
DDA 5005A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight (Agilent) DDA 5005A XXL Disk Drive Analyzer is a instrument purpose-built for testing, characterizing, and troubleshooting disk drive performance. Integrating LeCroy's X-Stream architecture with SiGe digitizer-on-chip technology and a specialized high-speed streaming bus, this analyzer captures and processes complex drive signals with exceptional fidelity. The XXL configuration delivers extended acquisition memory - up to 25,000 sectors of data - enabling capture of complete drive operations for detailed failure analysis and performance validation.


Technical Specifications



  • Analog Bandwidth: 5 GHz (-3 dB at 50 Ω)

  • Input Channels: 4

  • Sample Rate: 10 GS/s per channel (4-channel mode); 20 GS/s (dual-channel mode)

  • Acquisition Memory: 100 Mpts (2-channel mode); 5 ms capture time at 20 GS/s dual-channel; up to 25,000 sectors with XXL

  • Trigger Modes: Normal, Auto, Single, Stop

  • Trigger Sources: Any input channel, External, Ext x10, Ext/10, Line

  • Max Trigger Frequency: 5 GHz (Edge Trigger); 750 MHz (SMART Trigger)

  • Trigger Bandwidth: 5 GHz

  • Input Impedance: 50 Ω ±1.5%

  • Input Coupling: DC, GND

  • Maximum Input Voltage: ±4 Vpeak (50 Ω)

  • Vertical Resolution: 8 bits; up to 11 bits with Enhanced Resolution (ERES)

  • Sensitivity: 2 mV–1 V/div fully variable

  • Offset Range: ±700 mV @ 2 mV–4.95 mV/div

  • Bandwidth Limiter: 20 MHz, 200 MHz, 1 GHz, 3 GHz, 4 GHz

  • Display: 10.4" color TFT-LCD (800 x 600 SVGA); touch panel; supports up to eight math traces

  • Averaging: Summed and Continuous modes

  • Envelope Capture: Up to 1 million sweeps


Key Features



  • Disk-specific trigger architecture qualifies signals on index and captures full sector sequences

  • Extended XXL memory enables acquisition of multiple complete drive operations without data loss

  • Enhanced Resolution (ERES) mode extends vertical resolution to 11 bits for low-amplitude signal detail

  • Programmable bandwidth limiting (20 MHz to 4 GHz) reduces noise on narrowband measurements


Connectivity & Integration



  • 100Base-T Ethernet

  • USB ports

  • 3.5" floppy drive

  • GPIB interface (optional)

  • Optional built-in graphics printer

Specifications

ParameterValue
Frequency RangeDC to 5.0 GHz

Keysight / Agilent DDA 5005A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent DDA 5005A. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keysight / Agilent DDA 5005A faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Keysight / Agilent DDA 5005A price

This Keysight / Agilent DDA 5005A is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent DDA 5005A calibration cost

NIST-traceable calibration for the Keysight / Agilent DDA 5005A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →