The Agilent/HP ESA-E Series spectrum analyzers (E4401B, E4402B, E4403B, E4404B, E4405B) deliver speed, dynamic range, and accuracy across RF and microwave measurement tasks. Built for R&D, manufacturing, and field service, these instruments provide signal analysis with configurable measurement personalities and optional enhancements.
Technical Specifications
Frequency Range- E4401B: 9 kHz to 1.5 GHz (50 Ω); 1 MHz to 1.5 GHz (75 Ω)
- E4402B: 9 kHz to 3.0 GHz (50 Ω); Option UKB: 100 Hz to 3 GHz (DC coupled), 100 kHz to 3 GHz (AC coupled)
- E4403B: 9 kHz to 3.0 GHz
- E4404B: 9 kHz to 6.7 GHz (DC coupled); Option UKB: 100 Hz to 6.7 GHz (DC coupled), 100 kHz to 6.7 GHz (AC coupled)
- E4405B: 9 kHz to 13.2 GHz (DC coupled); Option UKB: 100 Hz to 13.2 GHz (DC coupled), 100 kHz to 13.2 GHz (AC coupled) Frequency Reference (Option 1D5)
- Stability: ±5×10⁻⁶ (temperature), ±2×10⁻⁶/year (aging)
- Settability: ±5×10⁻⁷ Frequency Readout Accuracy
- ±(frequency indication × frequency reference error + span accuracy + 15% of RBW + 10 Hz + 1 Hz × N⁴), where N⁴ = LO harmonic mixing mode Marker Frequency Counter
- Accuracy: ±(marker frequency × frequency reference error + counter resolution)
- Resolution: Selectable 1 Hz to 100 kHz Frequency Span
- Range: 0 Hz (zero span) to analyzer maximum
- Resolution: Four digits or 2 Hz × N⁴, whichever is greater
- Accuracy: ±0.5% of span (8192 sweep points) Sweep Time
- Range: 1 ms to 4000 s Resolution Bandwidth (RBW)
- Standard: 1 kHz to 5 MHz (–3 dB) in 1-3-10 sequence
- Option 1DR: 10 Hz, 30 Hz, 100 Hz, 300 Hz (–3 dB) bandwidths available Video Bandwidth (VBW)
- 30 Hz to 3 MHz in 1-3-10 sequence Amplitude Specifications
- Measurement range: Displayed Average Noise Level (DANL) to maximum safe input
- DANL: –167 dBm (E4405B with internal preamp)
- 1 dB Gain Compression: ≥50 MHz at 0 dBm; ≥6.7 GHz at –3 dBm; ≥13.2 GHz at –5 dBm
- Absolute Amplitude Accuracy (50 MHz): ±0.34 dB
- Overall Amplitude Accuracy: ±0.4 dB (instantaneous), ±1 dB (up to 3 GHz), ±2.5 dB (up to 26.5 GHz) Noise Sidebands (1 kHz RBW, 30 Hz VBW, sample detector)
- ≥10 kHz offset: ≤–90 dBc/Hz + 20 Log N⁴
- ≥20 kHz offset: ≤–98 dBc/Hz + 20 Log N⁴
- ≥30 kHz offset: ≤–100 dBc/Hz + 20 Log N⁴
- ≥100 kHz offset: ≤–112 dBc
Typical Applications Signal analysis, component characterization, interference detection, modulation assessment, and noise floor evaluation across research, production test, and field service environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | E4401B: 9 kHz to 1.5 GHz |
| E4402B | 9 kHz to 3.0 GHz |
| E4403B | 9 kHz to 3.0 GHz |
| E4404B | 9 kHz to 6.7 GHz |
| E4405B | 9 kHz to 13.2 GHz | Power Range (dBm): –167 dBm to 0 dBm (1 dB compression point at ≥50 MHz) |
Agilent E4401B/E4402B/E4403B/E4404B/E4405B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent E4401B/E4402B/E4403B/E4404B/E4405B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent E4401B/E4402B/E4403B/E4404B/E4405B price
This Agilent E4401B/E4402B/E4403B/E4404B/E4405B is listed at $100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent E4401B/E4402B/E4403B/E4404B/E4405B calibration cost
NIST-traceable calibration for the Agilent E4401B/E4402B/E4403B/E4404B/E4405B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →