Agilent / Keysight E4407B 26.5 GHz ESA-E Spectrum Analyzer

The Agilent/Keysight E4407B ESA-E spectrum analyzer offers a frequency range of 9 kHz to 26.5 GHz, providing comprehensive signal analysis for various applications. It features a wide dynamic range, excellent sensitivity, and versatile measurement capabilities. Ideal for testing and analyzing RF and microwave signals in research, development, and manufacturing environments.

Model
Agilent E4407B
Calibration
Available on request
Price
$7,254
RFQ ref
E4407B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight E4407B ESA-E Spectrum Analyzer delivers signal analysis from 9 kHz to 26.5 GHz with internal mixing, extending to 110 GHz and 325 GHz using external mixers. Built for R&D, manufacturing, and field testing, this portable analyzer provides ±1 dB amplitude accuracy to 3 GHz and ±2.5 dB to 26.5 GHz, with DANL reaching -167 dBm using the internal preamp. The instrument achieves 99 dB third-order dynamic range and delivers up to 40 measurements per second with 1 ms RF sweep time.


Resolution bandwidth spans 1 kHz standard (10 Hz optional), with variable sweep points from 101 to 8192. The 50 Ω type N input accepts continuous power to +30 dBm and peak pulse power to +50 dBm. Frequency reference stability is ±5×10–6 across temperature.


Operation via 195–250 Vrms AC or 12–20 Vdc, consuming <300 W AC or <200 W DC. Five-minute warm-up ensures guaranteed measurement accuracy.


Technical Specifications



  • Frequency Range: 9 kHz to 26.5 GHz (internal mixing); extends to 110 GHz and 325 GHz with external mixers

  • Span: 0 Hz (zero span) to 26.5 GHz; 100 Hz minimum for swept operation

  • Resolution Bandwidth: 1 kHz standard; 10 Hz optional; EMI bandwidths at 9 kHz and 120 kHz (–6 dB); Option 1DR adds 10, 30, 100, 300 Hz (–3 dB) and 200 Hz (–6 dB) EMI

  • Amplitude Accuracy: ±1 dB to 3 GHz; ±2.5 dB to 26.5 GHz; 0.4 dB overall; ±2 dB response (13.2–26.5 GHz)

  • Noise Floor: -167 dBm DANL (internal preamp); -155 dBm (10 Hz RBW, optional preamp); -137 to -132 dBm without preamp

  • Dynamic Range: 99 dB third-order (+12 dBm TOI)

  • Sweep Points: 101 to 8192 points

  • Measurement Speed: 40 updates/sec; 1 ms RF sweep time; 33 ms local/remote update rate

  • Input: 50 Ω type N (f); +30 dBm continuous; +50 dBm peak pulse

  • Frequency Reference: ±2×10–6/year aging; ±5×10–6 temperature stability; ±5×10–7 settability

  • Trigger Modes: Free run, single, line, video, offset, delayed, external


Key Features



  • Zero-span mode for time-domain analysis

  • Settable trigger options for synchronized measurements

  • 40 measurements per second local and remote via GPIB

  • Optional digital RBW filters for EMI precompliance

  • AC and DC power operation for field deployment


Electrical Specifications



  • AC Power: 195–250 Vrms, 47–66 Hz; <300 W consumption

  • DC Power: 12–20 Vdc; <200 W consumption

  • Warm-up Time: 5 minutes


Compatibility & Integration



  • IEEE-488 GPIB interface (Option A4H)

  • 25-pin D-SUB printer port

  • External mixer support via option AYZ

Specifications

ParameterValue
Frequency Range9 kHz to 26.5 GHz
Power Range (dBm)-167 dBm to +30 dBm
Voltage / Current Range+30 dBm and 0 Vdc (input maximum)

Agilent E4407B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent E4407B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent E4407B price

This Agilent E4407B is listed at $7,253.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent E4407B calibration cost

NIST-traceable calibration for the Agilent E4407B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →