Agilent / Keysight E4411B 1.5GHz ESA-L Spectrum Analyzer
Agilent / Keysight Spectrum Analyzers. Frequency range: 9 kHz to 1.5 GHz, Accuracy: ±1% of span, Accuracy: ±1%.
- Model
- Agilent E4411B
- Calibration
- Available on request
- Price
- $2,997
- RFQ ref
- E4411B
This unit
The Agilent/Keysight E4411B ESA-L Spectrum Analyzer is a 1.5 GHz spectrum analyzer engineered for RF signal characterization across communications, research, and development environments. Operating from 9 kHz to 1.5 GHz, it delivers frequency readout accuracy of ±(frequency readout × frequency reference error + span accuracy + 15% of RBW + 10 Hz) with a frequency reference aging rate of ±2 × 10⁻⁶/year. The instrument provides amplitude measurement capability with ±0.4 dB accuracy at reference settings and supports input attenuation from 0 to 60 dB in 5 dB steps.
Resolution bandwidth spans 100 Hz to 5 MHz with ±10% accuracy across 1 kHz to 1 MHz settings, while video bandwidth ranges from 30 Hz to 1 MHz. Sweep performance includes 5 ms to 2000 sec sweep times with ±1% accuracy and supports free run, single, line, video, delayed trigger, and external sweep modes. Phase noise performance reaches −101 dBc/Hz at 1 GHz with 10 kHz offset and −122 dBc/Hz at 100 kHz offset.
The analyzer accepts peak pulse power up to +30 dBm with ≥15 dB attenuation and features a high-resolution color display optimized for signal visualization. Rapid warm-up time enables quick measurement availability, while the rugged design suits both benchtop and field deployment. PowerSuite one-button RF power measurements are standard.
Technical Specifications
Frequency Performance- Frequency range: 9 kHz to 1.5 GHz
- Frequency span: 0 Hz (zero span) and 100 Hz to 1.5 GHz
- Frequency span accuracy: ±1% of span
- Frequency reference aging: ±2 × 10⁻⁶/year, ±1.0 × 10⁻⁷/day
- Frequency reference temperature stability: ±5 × 10⁻⁶
- Frequency reference settability: ±5 × 10⁻⁷
- Phase noise at 1 GHz (10 kHz offset): −101 dBc/Hz
- Phase noise at 1 GHz (100 kHz offset): −122 dBc/Hz Amplitude Specifications
- Amplitude accuracy (reference settings): ±0.4 dB
- Input attenuator range: 0 to 60 dB in 5 dB steps
- 1-dB gain compression point: 0 dBm
- Maximum safe input level (≥15 dB attenuation): +30 dBm
- Peak pulse power (≥15 dB attenuation): +30 dBm
- Third-order intermodulation (TOI): +7.5 dBm Resolution & Video Bandwidth
- Resolution bandwidth range: 100 Hz to 5 MHz (1-3-10 sequence)
- RBW accuracy (1 kHz to 1 MHz): ±10%
- RBW accuracy (9 kHz, 120 kHz, 3 MHz): ±15%
- RBW selectivity (60 dB/3 dB ratio): <15:1
- Video bandwidth range: 30 Hz to 1 MHz (1-3-10 sequence) Sweep & Trigger
- Sweep time range: 5 ms to 2000 sec
- Sweep time accuracy: ±1%
- Sweep trigger modes: Free run, single, line, video, delayed trigger, external
Key Features
- Five-millisecond full-span RF sweep capability
- Marker frequency counter with accuracy of ±(marker frequency × frequency reference error + counter resolution)
- Narrow resolution bandwidth measurement support
- User-friendly interface with high-resolution color display
- Field-deployable rugged construction
Typical Applications
- RF signal analysis in communications systems
- Research and development testing
- Field measurement and troubleshooting
Compatibility & Integration PowerSuite one-button RF power measurement functionality is included as standard.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 1.5 GHz | Power Range (dBm): '-130 dBm to +30 dBm |
Agilent E4411B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent E4411B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent E4411B price
This Agilent E4411B is listed at $2,997. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent E4411B calibration cost
NIST-traceable calibration for the Agilent E4411B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →