Stanford Research FS740 GPS/GNSS Time and Frequency System

The Stanford Research Systems FS740 is a GPS/GNSS time and frequency system that provides accurate and reliable timing signals synchronized to GPS or other GNSS constellations. It offers high-precision frequency outputs and precise time synchronization for various applications.

Model
Stanford Research Systems FS740
Calibration
Available on request
Price
$5,170
Status
In stock
RFQ ref
FS740
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems FS740 is a GPS/GNSS-disciplined time and frequency reference system delivering 10 MHz outputs with long-term stability better than 1 × 10⁻¹³. It integrates a multi-constellation GNSS receiver (GPS, GLONASS, BEIDOU, GALILEO) to discipline its internal oscillator, providing phase-coherent timing and frequency synthesis across a range of output formats.


Technical Specifications

Disciplined Oscillator & Stability

  • GPS/GNSS-disciplined 10 MHz reference

  • Long-term frequency stability: Better than 1 × 10⁻¹³

  • Standard timebase short-term stability: 1 × 10⁻⁹; phase noise (SSB) <−105 dBc/Hz at 10 Hz offset

  • Optional OCXO timebase: Short-term stability 1 × 10⁻¹¹; phase noise <−130 dBc/Hz at 10 Hz offset; holdover <40 ps/24 hr

  • Optional Rubidium timebase: Short-term stability 1 × 10⁻¹²; phase noise 1 μs/day without GNSS Frequency Measurement & Synthesis

  • 12 digit/s frequency counter with 1 × 10⁻¹¹ precision (1 s), 1 × 10⁻¹² (10 s), 1 × 10⁻¹³ (100 s)

  • DDS synthesized outputs: 1 μHz to 30.1 MHz (1 μHz resolution) or fixed 100 MHz

  • Low-jitter pulse outputs: 1 mHz to 25 MHz with <50 ps rms jitter; pulse width 5 ns to period−5 ns at 10 ps resolution

  • IRIG-B timecode output

  • Output impedance: 50 Ω; harmonics −40 dBc; spurious −70 dB

  • Optional rear-panel boards: Up to 15 additional 10 MHz, sine, or pulse output copies Time Tagging

  • Event time tagging with 1 ps resolution and ~10 ns rms error relative to UTC or GPS time Interfaces & Power

  • Ethernet (10/100 Base-T, TCP/IP, DHCP) and RS-232

  • Front-panel graphical display; rear connectors for antenna, measurement input, source outputs

  • AC input: 90–264 VAC, 47–63 Hz with PFC; 90 W consumption


Key Features



  • Multi-constellation GNSS receiver with automatic constellation selection

  • Selectable timebase options for precision-to-stability tradeoffs

  • Arbitrary waveform synthesis (sine, ramp, triangle) via AUX output

  • Microsecond-level holdover performance with optional Rubidium upgrade

  • Picosecond-resolution event time-tagging for synchronization applications


Typical Applications



  • Frequency metrology and calibration laboratories

  • Network synchronization and PTP grandmaster clocking

  • Cellular base station timing (4G/5G)

  • Broadcast and satellite communication standards

  • Physics experiments requiring phase coherence


Compatibility & Integration The FS740 communicates via standard Ethernet (TCP/IP) and RS-232 for remote operation. Its configurable outputs accommodate both analog (sine) and digital (pulse, IRIG-B) timing signals, enabling integration with legacy and modern test systems. The system accepts external GNSS antennas and supports event input for precise time-tagging of external signals.

Specifications

ParameterValue
Frequency Range1 μHz to 30.1 MHz (DDS outputs)
1 mHz to 25 MHz (pulse outputs) | Voltage / Current Range47–63 Hz, 90–264 VAC

Stanford Research Systems FS740 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems FS740. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Stanford Research Systems FS740 price

This Stanford Research Systems FS740 is listed at $5,170. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems FS740 calibration cost

NIST-traceable calibration for the Stanford Research Systems FS740 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents