Exfo FVA-80-D-32 Singlemode Variable Attenuator

The Exfo FVA-80-D-32 is a Singlemode Variable Attenuator designed for precise control of optical signal strength. It operates in the 1250-1650 nm wavelength range, offering 32 dB attenuation and exceptional return loss. Ideal for laboratory and field applications, it ensures accurate power level adjustments in fiber optic systems.

Model
Exfo FVA-80-D-32
Calibration
Available on request
Price
$1,450
Status
In stock
RFQ ref
FVA-80-D-32
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Exfo FVA-80-D-32 is a singlemode variable optical attenuator that delivers precise control of optical signal strength across fiber optic networks. This instrument provides 32 dB of attenuation with 0.01 dB optical resolution, making it suitable for laboratory and field applications requiring accurate power level adjustments. The FVA-80-D-32 excels at simulating system loss, performing optical margin analysis, and conducting acceptance testing of communication systems.

Technical Specifications

Wavelength Range: 1250–1650 nm; calibrated for 1300 nm and 1550 nm

Attenuation Range: 32 dB maximum

Insertion Loss: Less than 3.0 dB

Optical Resolution: 0.01 dB

Operating Temperature: 0 °C to 40 °C

Storage Temperature: −40 °C to 70 °C

Humidity: 0% to 80% non-condensing

Power Supply: AC operation

Key Features

Absolute loss mode with insertion loss better than 3.0 dB

Two relative attenuation display modes for flexible measurement reporting

Step/scan mode enabling attenuation value modifications in loss and ref/dBm modes

Programmable mode supporting up to 60 attenuation changes with delays up to 23 hours, 59 minutes, and 59 seconds

Manual front panel keypad control with fine/coarse adjustment capability

Programmable control via RS-232 and IEEE-488 (GPIB) interfaces

Designed for portability across laboratory and field environments

Typical Applications

System loss simulation for fiber optic networks

Optical margin and performance analysis

Acceptance testing and validation of communication systems

Power level control and adjustment in test setups

Compatibility & Integration RS-232 and IEEE-488 (GPIB) interfaces enable both manual and remote programmable control. Singlemode calibration is performed using FC/UPC connectors. Optional computer interface configurations are available for extended integration into automated test systems.

Specifications

ParameterValue
Voltage / Current RangeAC power | Wavelength Range: 1250–1650 nm (calibrated for 1300 nm and 1550 nm)

Exfo FVA-80-D-32 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Exfo FVA-80-D-32. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Exfo FVA-80-D-32 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

Exfo FVA-80-D-32 price

This Exfo FVA-80-D-32 is listed at $1,450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Exfo FVA-80-D-32 calibration cost

NIST-traceable calibration for the Exfo FVA-80-D-32 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents