JDS Uniphase HA9 - HA097E+10KFP1
JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.1 dB.
- Model
- JDS Uniphase HA9 - HA097E+10KFP1
- Calibration
- Available on request
- Price
- $1,650
- Status
- In stock
- RFQ ref
- HA9 - HA097E+10KFP1
This unit
The JDS Uniphase HA9
HA097E+10KFP1 is a programmable optical attenuator engineered for precision optical power control in laboratory and field test environments. It delivers up to 100 dB attenuation with 0.01 dB resolution and ±0.1 dB accuracy, enabling reliable performance across power meter calibration, bit error rate testing, loss simulation, and DWDM system characterization.
Technical Specifications
Attenuation Range: 0–100 dB
Resolution: 0.01 dB nominal
Accuracy: ±0.1 dB
Repeatability: 0.01 dB
Wavelength Range: 1200–1700 nm standard
Polarization Dependent Loss (PDL): 0.03 dB typical
Wavelength Dependence: 90 dB fast-access attenuation
High return loss and low spectral ripple suitable for CATV AM systems
Typical Applications
Power meter linearity calibration
Bit error rate (BER) testing
Analog transmission characterization
Optical loss simulation in fiber links
EDFA output power characterization
Multichannel AM systems
High bit-rate PCM systems
DWDM system characterization
Compatibility & Integration The attenuator accepts GPIB and RS232 control protocols, enabling integration into automated test benches and system-level measurement setups. Command syntax aligns with HP8156A standards, supporting straightforward migration within existing HP/Agilent-compatible test frameworks.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | Up to 1000 mW (30 dBm) input | Wavelength Range: 1200–1700 nm |
JDS Uniphase HA9 - HA097E+10KFP1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9 - HA097E+10KFP1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase HA9 - HA097E+10KFP1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase HA9 - HA097E+10KFP1 price
This JDS Uniphase HA9 - HA097E+10KFP1 is listed at $1,650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase HA9 - HA097E+10KFP1 calibration cost
NIST-traceable calibration for the JDS Uniphase HA9 - HA097E+10KFP1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →