JDS Uniphase HA9 - HA097E+10KFP1

JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.1 dB.

Model
JDS Uniphase HA9 - HA097E+10KFP1
Calibration
Available on request
Price
$1,650
Status
In stock
RFQ ref
HA9 - HA097E+10KFP1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase HA9

HA097E+10KFP1 is a programmable optical attenuator engineered for precision optical power control in laboratory and field test environments. It delivers up to 100 dB attenuation with 0.01 dB resolution and ±0.1 dB accuracy, enabling reliable performance across power meter calibration, bit error rate testing, loss simulation, and DWDM system characterization.

Technical Specifications

Attenuation Range: 0–100 dB

Resolution: 0.01 dB nominal

Accuracy: ±0.1 dB

Repeatability: 0.01 dB

Wavelength Range: 1200–1700 nm standard

Polarization Dependent Loss (PDL): 0.03 dB typical

Wavelength Dependence: 90 dB fast-access attenuation

High return loss and low spectral ripple suitable for CATV AM systems

Typical Applications

Power meter linearity calibration

Bit error rate (BER) testing

Analog transmission characterization

Optical loss simulation in fiber links

EDFA output power characterization

Multichannel AM systems

High bit-rate PCM systems

DWDM system characterization

Compatibility & Integration The attenuator accepts GPIB and RS232 control protocols, enabling integration into automated test benches and system-level measurement setups. Command syntax aligns with HP8156A standards, supporting straightforward migration within existing HP/Agilent-compatible test frameworks.

Specifications

ParameterValue
Power Range (dBm)Up to 1000 mW (30 dBm) input | Wavelength Range: 1200–1700 nm

JDS Uniphase HA9 - HA097E+10KFP1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9 - HA097E+10KFP1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase HA9 - HA097E+10KFP1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase HA9 - HA097E+10KFP1 price

This JDS Uniphase HA9 - HA097E+10KFP1 is listed at $1,650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase HA9 - HA097E+10KFP1 calibration cost

NIST-traceable calibration for the JDS Uniphase HA9 - HA097E+10KFP1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents