JDS Uniphase HA9W1+20KSC1

JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ± 0.1 dB.

Model
JDS Uniphase HA9W1+20KSC1
Calibration
Available on request
Price
$2,300
Status
In stock
RFQ ref
HA9W1+20KSC1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase HA9W1+20KSC1 is a programmable optical attenuator for precision control of optical power in telecommunications and laboratory testing. It delivers up to 100 dB attenuation with 0.01 dB resolution across a 1200–1700 nm wavelength range, making it suitable for power level adjustments in DWDM characterization, bit error rate testing, and general optical test work.

Technical Specifications

Attenuation Range: Up to 100 dB

Resolution: 0.01 dB nominal

Accuracy: ± 0.1 dB

Wavelength Range: 1200–1700 nm (750–1700 nm available with reduced 60 dB range)

Fiber Type: 50/125 µm multimode

Optical Interface: SC/PC

Insertion Loss: Typically 60 dB analog

Internal Reflectance: Better than 60 dB

Beam Blocking Switch: Built-in, >90 dB attenuation

Key Features

Coupler options: 2/98, 10/90, 30/70, or 50/50 configurations available

Optional built-in couplers and switches for output tapping or dual-channel access

Minimal cavity effects with discrete internal optical reflections controlled to >60 dB

Fast infinite attenuation via mechanical beam blocking switch

5 V front-panel driver key for external or internal switch control

Typical Applications

Power meter testing and calibration

Bit error rate (BER) testing

Multichannel AM system characterization

High bit-rate digital PCM systems

DWDM system validation and characterization

Compatibility & Integration Command control via SCPI/HP8156A-compatible command set, GPIB/IEEE-488, RS232-C, or front-panel keyboard entry. Integrates with external test systems requiring precise optical attenuation control and monitoring.

Specifications

ParameterValue
Voltage / Current Range'+5 V rear panel output | Wavelength Range: 750–1700 nm or 1200–1700 nm

JDS Uniphase HA9W1+20KSC1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9W1+20KSC1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase HA9W1+20KSC1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase HA9W1+20KSC1 price

This JDS Uniphase HA9W1+20KSC1 is listed at $2,300. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase HA9W1+20KSC1 calibration cost

NIST-traceable calibration for the JDS Uniphase HA9W1+20KSC1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents