JDS Uniphase HA9W1+20KSC1
JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ± 0.1 dB.
- Model
- JDS Uniphase HA9W1+20KSC1
- Calibration
- Available on request
- Price
- $2,300
- Status
- In stock
- RFQ ref
- HA9W1+20KSC1
This unit
The JDS Uniphase HA9W1+20KSC1 is a programmable optical attenuator for precision control of optical power in telecommunications and laboratory testing. It delivers up to 100 dB attenuation with 0.01 dB resolution across a 1200–1700 nm wavelength range, making it suitable for power level adjustments in DWDM characterization, bit error rate testing, and general optical test work.
Technical Specifications
Attenuation Range: Up to 100 dB
Resolution: 0.01 dB nominal
Accuracy: ± 0.1 dB
Wavelength Range: 1200–1700 nm (750–1700 nm available with reduced 60 dB range)
Fiber Type: 50/125 µm multimode
Optical Interface: SC/PC
Insertion Loss: Typically 60 dB analog
Internal Reflectance: Better than 60 dB
Beam Blocking Switch: Built-in, >90 dB attenuation
Key Features
Coupler options: 2/98, 10/90, 30/70, or 50/50 configurations available
Optional built-in couplers and switches for output tapping or dual-channel access
Minimal cavity effects with discrete internal optical reflections controlled to >60 dB
Fast infinite attenuation via mechanical beam blocking switch
5 V front-panel driver key for external or internal switch control
Typical Applications
Power meter testing and calibration
Bit error rate (BER) testing
Multichannel AM system characterization
High bit-rate digital PCM systems
DWDM system validation and characterization
Compatibility & Integration Command control via SCPI/HP8156A-compatible command set, GPIB/IEEE-488, RS232-C, or front-panel keyboard entry. Integrates with external test systems requiring precise optical attenuation control and monitoring.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | '+5 V rear panel output | Wavelength Range: 750–1700 nm or 1200–1700 nm |
JDS Uniphase HA9W1+20KSC1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9W1+20KSC1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase HA9W1+20KSC1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase HA9W1+20KSC1 price
This JDS Uniphase HA9W1+20KSC1 is listed at $2,300. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase HA9W1+20KSC1 calibration cost
NIST-traceable calibration for the JDS Uniphase HA9W1+20KSC1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →