Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 Accelerometer ADC Module - Conformal Coated
Curtiss-Wright / ACRA Control Data Acquisition Systems (DAQ). Voltage: 24 V, Bandwidth: 6 kHz (AAAF filter).
- Model
- Curtiss-Wright / ACRA Control KAD/ADC/106/C/00
- Calibration
- Available on request
- Price
- $1,450
- Status
- In stock
- RFQ ref
- KAD/ADC/106/C/00
This unit
The Curtiss-Wright/ACRA Control KAD/ADC/106/C/00 is a conformal-coated accelerometer ADC module that conditions and digitizes sensor signals for precision data acquisition in demanding environments. It processes six dedicated accelerometer channels plus two general-purpose differential inputs with simultaneous 16-bit sampling and programmable digital filtering.
Technical Specifications Input Channels & Signal Conditioning
Six accelerometer inputs with DC-reject and constant current source excitation (3.6 mA typical)
Supports ICP, Isotron, Piezotron, and Deltatron sensor types
Two differential-ended analog channels for general signal measurement
Accelerometer input ranges: ±1 V, ±10 V with four gain settings (Gain 1: -10 V to +10 V; Gain 10: -1 V to +1 V; Gain 100: -100 mV to +100 mV; Gain 1000: -10 mV to +10 mV)
Differential input ranges: ±10 mV to ±10 V
Constant current source compliance voltage: 24 V
Channel isolation: short on any accelerometer input does not affect others Sampling & Filtering
Analog sampling rate: 2 to 24000 Sps
Oversampling rate: 96 kSps to 192 kSps
16-bit simultaneous sampling on each channel
Individual channel sampling rates settable as powers of two relative to each other
Cascaded half-band FIR filters followed by 8th order Butterworth IIR filter
Default cutoff frequency: fc = fs / 4
Maximum bandwidth: 6 kHz (AAAF filter)
User-programmable filter cutoff frequency Electrical Performance
Input impedance (at 3 kHz): 0.8–1 MΩ (powered off); 250–300 kΩ (powered on); 10–10 MΩ (powered on DC)
Common mode voltage range: -10 V to +10 V
CMRR: 50 dB (0 ≤ f ≤ fc)
Crosstalk: -72 to -60 dB (Gains 1, 10, 100); -45 dB (Gain 1000)
DC error (2.2 kΩ load): 1.6 mA
DC current noise: 3 mVrms Physical
Mass: 100 g (3.53 oz)
Conformal coating applied
Key Features
Independent channel isolation prevents crosstalk propagation across accelerometer inputs
Programmable gain and sampling architecture adapts to diverse sensor and bandwidth requirements
Constant current excitation optimizes conditioning for ICP and equivalent sensor families
Flexible sampling rate assignment enables multi-rate data capture within single module
Typical Applications
Vibration monitoring and machinery diagnostics
Structural health monitoring
Transient event capture requiring synchronized multi-channel acquisition
Environmental stress screening (ESS) in avionics and defense platforms
Compatibility & Integration Designed for integration with Curtiss-Wright/ACRA Control systems supporting ICP sensor standards. Conformal coating provides protection in moisture-rich and salt-fog environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 6 kHz | Voltage / Current Range: ±1 V to ±10 V (accelerometer) |
Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Curtiss-Wright / ACRA Control KAD/ADC/106/C/00. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 price
This Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 is listed at $1,450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 calibration cost
NIST-traceable calibration for the Curtiss-Wright / ACRA Control KAD/ADC/106/C/00 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →