Keithley KPCI-3102 Low Gain Analog I/O Board

Keithley Data Acquisition Systems (DAQ). Channel: gain queue for non-sequential channel sampling wit.

Model
Keithley KPCI-3102
Calibration
Available on request
Price
$450
Status
In stock
RFQ ref
KPCI-3102
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley KPCI-3102 is a PCI-bus data acquisition board engineered for low-gain analog input and output applications in test, measurement, process control, and automation systems. It delivers 12-bit analog input resolution at up to 225 kS/s throughput, configurable 16 single-ended or 8 differential input channels, 2 analog outputs with 16-bit resolution, 23 digital I/O lines, and 4 counter/timer channels.

Technical Specifications Analog Input

16 single-ended or 8 differential channels

12-bit resolution

Configurable ranges: ±1.25 V, ±2.5 V, ±5 V, ±10 V (bipolar); 0–1.25 V, 0–2.5 V, 0–5 V, 0–10 V (unipolar)

Gain settings: 1, 2, 4, 8

Throughput: 225 kS/s maximum

1024-location channel-gain queue for non-sequential channel sampling with different gains

Continuous paced and triggered acquisition modes

Pre-trigger, post-trigger, and about-trigger support with external trigger capability

Amp Low connection for pseudo-differential input referencing Analog Output

2 channels, 16-bit resolution

Output ranges: ±5 V, ±10 V, 0–5 V, 0–10 V

Outputs initialize to 0 V at power-up Digital I/O

23 total lines: two 8-bit ports (A, B) and one 7-bit port (C)

Ports A and B combinable into a virtual 16-line port

Scanning to 3 MHz

Digital output drive: 12 mA sink, 15 mA source Counter/Timers

4 channels, 16-bit resolution

Event counting, one-shot/frequency output, frequency measurement

Internal and external cascading support

Key Features

68-pin Amp connector for I/O

Software-configurable input ranges and gains

Manual and automatic calibration utilities

Bundled 32-bit DriverLINX drivers, TestPoint, LabVIEW VIs, ExceLINX, VisualSCOPE

Typical Applications Data acquisition, industrial control, sensor signal conditioning, frequency measurement, and multi-channel signal routing in laboratory and field deployments.

Compatibility & Integration PCI-bus interface. Operating temperature: 0°C to 70°C. Storage temperature: –25°C to 85°C. Relative humidity: up to 95% non-condensing. Board dimensions: 8.5 inches × 4.2 inches.

Specifications

ParameterValue
Voltage / Current Range±1.25 V, ±10 V, ±10 V (input bipolar)

Keithley KPCI-3102 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley KPCI-3102. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keithley KPCI-3102 price

This Keithley KPCI-3102 is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley KPCI-3102 calibration cost

NIST-traceable calibration for the Keithley KPCI-3102 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents