ILX Lightwave LDC-3752M: 2/4 A Laser Diode Controller

The ILX Lightwave LDC-3752M is a precision laser diode controller capable of delivering 2A or 4A of current. It features advanced laser diode protection, high stability, and user-friendly interface for demanding laser control applications.

Model
ILX Lightwave LDC-3752M
Calibration
Available on request
Price
$1,970
Status
In stock
RFQ ref
LDC-3752M
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The ILX Lightwave LDC-3752M is a precision laser diode controller combining high-stability current delivery with integrated temperature management. It has dual-range current output (2A/4A), advanced laser protection, and hybrid P-I temperature control from −100°C to 199°C, serving demanding laboratory and production environments requiring simultaneous optical and thermal regulation.

Technical Specifications Laser Current Source

Dual current ranges: 2A / 4A

Setpoint accuracy: ±0.05%

Setpoint resolution: 40 µA (2A range) / 80 µA (4A range)

Noise and ripple: <10 µA

Short-term stability: <20 ppm

Compliance voltage: 10V

Low bandwidth mode: DC operation with external modulation to 15 kHz

High bandwidth mode: Modulation to 1 MHz for dithering and wavelength tuning

Constant power mode: Rear facet or external photodiode feedback

Analog modulation: Differential input for improved laser protection Temperature Controller

TEC output power: 32W

TEC output current: 4A

TEC output voltage: 8V

Temperature control range: −100°C to 199°C

Temperature stability: ±0.004°C (with calibrated sensor)

Temperature measurement accuracy: ±0.05°C (with calibrated sensor)

Temperature setpoint resolution: 0.01°C

Control loop: Hybrid P-I

Sensor types: Thermistor, IC, RTD

Control modes: Constant temperature, constant sensor, constant TE current

Key Features

Independent current limits with adjustable threshold

Slow-start turn-on circuitry

Adjustable compliance voltage

Intermittent contact protection

Output shorting relays and semiconductor switch

Isolated laser and temperature control power supplies

Fast output shut-off response

Power line surge and EFT transient protection

Redundant current limit

Temperature sensor or TE module open-circuit shutoff

Typical Applications

High-precision laser diode characterization

Wavelength-tuned optical systems

Production-line laser module testing

Research and development optical platforms

Compatibility & Integration Supports thermistor, IC, and RTD temperature sensors. Capable of measuring temperature, current, resistance, and voltage across TEC circuit.

Specifications

ParameterValue
Voltage / Current Range2A / 4A output

ILX Lightwave LDC-3752M — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the ILX Lightwave LDC-3752M. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common ILX Lightwave LDC-3752M faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

ILX Lightwave LDC-3752M price

This ILX Lightwave LDC-3752M is listed at $1,970. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

ILX Lightwave LDC-3752M calibration cost

NIST-traceable calibration for the ILX Lightwave LDC-3752M is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents