Agilent/Keysight M9800A

Agilent / Keysight Vector Network Analyzers.

Model
Keysight M9800A
Calibration
Available on request
Price
$3,750
RFQ ref
M9800A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight M9800A is a PXIe Vector Network Analyzer module delivering RF characterization across 9 kHz to 4.5 GHz. This modular instrument configures as a 2-, 4-, or 6-port VNA and cascades with other M980xA series modules to build multi-port systems supporting up to 50 ports within a single PXIe chassis. It enables multiport and multi-site testing with N-port error correction and electronic calibration (ECal) module support for rapid, accurate calibration cycles.


Technical Specifications

Frequency Range

  • 9 kHz to 4.5 GHz Port Configuration

  • Available as 2-port, 4-port, or 6-port VNA

  • Cascadable to 50 ports maximum per PXIe chassis Dynamic Range

  • 111 dB typical (9 kHz to 100 kHz)

  • 101 dB warranted specification (9 kHz to 100 kHz) IF Bandwidth

  • 10 Hz minimum Performance Operating Conditions

  • Module temperature: 37–50 °C (2-port), 40–53 °C (4-port), 43–56 °C (6-port)

  • Warm-up time: 60 minutes minimum with VNA application active


Key Features



  • Multiport error correction for accurate cascade measurements

  • Electronic calibration (ECal) module support

  • Intuitive graphical user interface matching Keysight network analyzers

  • Spectrum analysis and pulsed-RF measurement capabilities

  • PXIe modular architecture for flexible system scaling


Typical Applications



  • Multi-port RF device characterization

  • Multisite production test

  • Cascade and filter measurement

  • Component and subassembly validation across VHF through microwave frequencies


Compatibility & Integration System Requirements



  • Operating System: Windows 7 SP1 or Windows 10 (64-bit)

  • Processor: Intel i5 6th Generation or newer; Intel Xeon E3 v3 or newer

  • RAM: 4 GB minimum

  • Storage: 2 GB minimum available disk space

  • Display: 1024 × 768 minimum resolution

  • Keysight IO Libraries Suite: Version 2018 Update 1 or greater Chassis Integration

  • PXIe or PXI-H chassis required

  • Keysight M903xA embedded controller or equivalent

  • Supports 2×8, 4×4, or 1×8 PXIe system slot configurations

  • PCIe Tunneling required for PXIe/Streamline VNA operation

Keysight M9800A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight M9800A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keysight M9800A price

This Keysight M9800A is listed at $3,750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight M9800A calibration cost

NIST-traceable calibration for the Keysight M9800A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →