Anritsu MA2400xA – Thermal Sensors
The Anritsu MA2400xA series are thermal power sensors designed for accurate average power measurements from 10 MHz to 18 GHz, with a dynamic range of -70 dBm to +20 dBm, and are compatible with Anritsu power meters. They provide reliable and precise power measurements for various RF and microwave applications.
- Model
- Anritsu MA2400xA
- Calibration
- Available on request
- Price · starting from
- $850
- Status
- In stock
- RFQ ref
- MA2400xA
This unit
The Anritsu MA2400xA series are thermal power sensors engineered for precise average power measurements across RF and microwave frequencies. Built on Seebeck element technology, these sensors deliver true-RMS detection for any incident waveform by measuring thermal gradients and charge migration between dissimilar metals. Each sensor stores calibration factors and linearity correction data in onboard EEPROM, enabling automatic interpolation and correction by compatible power meters.
Technical Specifications Frequency Range
MA24002A: 10 MHz to 18 GHz
MA24004A: 10 MHz to 40 GHz
MA24005A: 10 MHz to 50 GHz Power Measurement
Dynamic range: −30 dBm to +20 dBm
Rise time: < 15 ms Sensor Linearity
< 1.8% (up to 18 GHz)
< 2.0% (up to 40 GHz)
< 2.5% (up to 50 GHz)
MA24005D specification: −30 to +15 dBm with additional 1% error above +15 dBm Standing Wave Ratio (SWR)
< 1.90 (10 to 50 MHz)
< 1.17 (50 to 150 MHz)
< 1.10 (150 MHz to 2 GHz)
< 1.15 (2 to 12.4 GHz)
< 1.20 (12.4 to 18 GHz)
< 1.25 (18 to 32 GHz)
< 1.30 (32 to 40 GHz)
< 1.40 (40 to 50 GHz)
Key Features
True-RMS detection delivers accurate average power measurements regardless of signal type
Precision RF connectors with hexagon coupling nuts for standard torque-wrench attachment
Internal EEPROM with stored calibration factors and linearity correction algorithms
Available connector options: N(m), K(m), V(m)
Typical Applications
RF and microwave power measurement across DC to millimeter-wave frequencies
Signal characterization in test and measurement environments
Power meter integration for automated correction and data logging
Compatibility & Integration Designed for use with Anritsu ML2430, ML2480, and ML2490 series power meters. Systems using ML2407A/08A or ML2437A/38A power meters require firmware revision 3.10 or higher when paired with MA24xxD and MA2400xA series sensors.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 18 GHz (MA24002A) |
| 10 MHz to 50 GHz (MA24005A) | Power Range (dBm) | −30 dBm to +20 dBm |
Anritsu MA2400xA — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2400xA. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2400xA price
This Anritsu MA2400xA is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2400xA calibration cost
NIST-traceable calibration for the Anritsu MA2400xA is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →