Anritsu MA2445D High Accuracy Sensor, 10MHz – 50GHz

The Anritsu MA2445D is a high accuracy power sensor designed for precise power measurements across a wide frequency range of 10 MHz to 50 GHz. Ideal for demanding applications, it ensures reliable and accurate results in laboratory and field environments.

Model
Anritsu MA2445D
Calibration
Available on request
Price · starting from
$3,530
Status
In stock
RFQ ref
MA2445D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MA2445D is a high-accuracy diode power sensor engineered for precise power measurements across 10 MHz to 50 GHz. It delivers an 87 dB dynamic range and 3.5% linearity across the full frequency span, making it suitable for both CW and TDMA measurement applications. The sensor integrates a built-in 3 dB attenuator to minimize input VSWR and stores calibration factors in EEPROM for automatic interpolation by compatible power meters.


Technical Specifications



  • Frequency Range: 10 MHz to 50 GHz

  • Power Range: −67 dBm to +20 dBm

  • Dynamic Range: 87 dB

  • Sensor Linearity: 3.5% from −67 dBm to +15 dBm; additional 1% accuracy above +15 dBm

  • Rise Time: <0.004 ms (4 µs)

  • RF Connector: V(m) with precision coupling nut for torque wrench attachment

  • Internal Attenuator: 3 dB built-in attenuation


SWR Performance by Frequency Band



  • <1.90 at 10–50 MHz

  • <1.17 at 50–150 MHz

  • <1.08 at 0.15–2 GHz

  • <1.16 at 2–12.4 GHz

  • <1.21 at 12.4–18 GHz

  • <1.29 at 18–32 GHz

  • <1.44 at 32–40 GHz

  • <1.50 at 40–50 GHz


Key Features



  • High-accuracy diode sensor design optimized for low measurement uncertainty across 87 dB dynamic range

  • Sub-microsecond rise time (4 µs) enables rapid settling for time-domain measurements

  • EEPROM-based calibration with automatic meter compensation eliminates manual correction overhead

  • Low VSWR achieved through precision V(m) connectors and integrated attenuator network

  • Specified linearity allows confident amplifier characterization from near-noise floor to high-power regimes


Typical Applications



  • Amplifier output power characterization and gain measurement

  • CW average power measurement across microwave and millimeter-wave frequencies

  • TDMA signal power assessment in mobile communications bands

  • High-dynamic-range power monitoring in component and system validation


Compatibility & Integration Designed for direct integration with Anritsu ML2430, ML2480, and ML2490 series power meters. EEPROM storage enables automatic calibration data retrieval, eliminating manual lookup procedures.

Specifications

ParameterValue
Frequency Range10 MHz to 50 GHz | Power Range (dBm): −67 dBm to +20 dBm

Anritsu MA2445D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2445D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu MA2445D price

This Anritsu MA2445D is listed at $3,530. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MA2445D calibration cost

NIST-traceable calibration for the Anritsu MA2445D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →