Anritsu MA2445D High Accuracy Sensor, 10MHz – 50GHz
The Anritsu MA2445D is a high accuracy power sensor designed for precise power measurements across a wide frequency range of 10 MHz to 50 GHz. Ideal for demanding applications, it ensures reliable and accurate results in laboratory and field environments.
- Model
- Anritsu MA2445D
- Calibration
- Available on request
- Price · starting from
- $3,530
- Status
- In stock
- RFQ ref
- MA2445D
This unit
The Anritsu MA2445D is a high-accuracy diode power sensor engineered for precise power measurements across 10 MHz to 50 GHz. It delivers an 87 dB dynamic range and 3.5% linearity across the full frequency span, making it suitable for both CW and TDMA measurement applications. The sensor integrates a built-in 3 dB attenuator to minimize input VSWR and stores calibration factors in EEPROM for automatic interpolation by compatible power meters.
Technical Specifications
- Frequency Range: 10 MHz to 50 GHz
- Power Range: −67 dBm to +20 dBm
- Dynamic Range: 87 dB
- Sensor Linearity: 3.5% from −67 dBm to +15 dBm; additional 1% accuracy above +15 dBm
- Rise Time: <0.004 ms (4 µs)
- RF Connector: V(m) with precision coupling nut for torque wrench attachment
- Internal Attenuator: 3 dB built-in attenuation
SWR Performance by Frequency Band
- <1.90 at 10–50 MHz
- <1.17 at 50–150 MHz
- <1.08 at 0.15–2 GHz
- <1.16 at 2–12.4 GHz
- <1.21 at 12.4–18 GHz
- <1.29 at 18–32 GHz
- <1.44 at 32–40 GHz
- <1.50 at 40–50 GHz
Key Features
- High-accuracy diode sensor design optimized for low measurement uncertainty across 87 dB dynamic range
- Sub-microsecond rise time (4 µs) enables rapid settling for time-domain measurements
- EEPROM-based calibration with automatic meter compensation eliminates manual correction overhead
- Low VSWR achieved through precision V(m) connectors and integrated attenuator network
- Specified linearity allows confident amplifier characterization from near-noise floor to high-power regimes
Typical Applications
- Amplifier output power characterization and gain measurement
- CW average power measurement across microwave and millimeter-wave frequencies
- TDMA signal power assessment in mobile communications bands
- High-dynamic-range power monitoring in component and system validation
Compatibility & Integration Designed for direct integration with Anritsu ML2430, ML2480, and ML2490 series power meters. EEPROM storage enables automatic calibration data retrieval, eliminating manual lookup procedures.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 50 GHz | Power Range (dBm): −67 dBm to +20 dBm |
Anritsu MA2445D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2445D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2445D price
This Anritsu MA2445D is listed at $3,530. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2445D calibration cost
NIST-traceable calibration for the Anritsu MA2445D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →