Anritsu MA2482D Universal Sensor, 10MHz to 18GHz
Anritsu RF Power Sensors. Frequency Range: 10 MHz to 18 GHz, Dynamic Range: 80 dB (six measurement ranges), Accuracy: <.
- Model
- Anritsu MA2482D
- Calibration
- Available on request
- Price · starting from
- $1,430
- Status
- In stock
- RFQ ref
- MA2482D
This unit
The Anritsu MA2482D is a true RMS power sensor engineered for broadband RF measurement across 10 MHz to 18 GHz. Its triple-diode architecture operates in the square-law region to deliver accurate average power readings of CW, multi-tone, and modulated waveforms - including 3G, 4G, and OFDM signals - independent of bandwidth. The 80 dB dynamic range spans six measurement ranges for versatile laboratory and production applications.
Technical Specifications
- Frequency Range: 10 MHz to 18 GHz
- Dynamic Range: 80 dB (six measurement ranges)
- Power Measurement Range: –60 dBm to +20 dBm
- Sensor Linearity: 3% (–60 to +20 dBm, 10 MHz to 18 GHz); 1.8% CW with Option 1
- Rise Time: <0.004 ms (Option 1 only)
- Temperature Accuracy: <1% (15°C to 35°C)
- Maximum Measurable Power: 100 mW
- VSWR: - <1.17 (10–150 MHz) - <1.12 (150 MHz–2 GHz) - <1.22 (2–12.4 GHz) - <1.25 (12.4–18 GHz)
- RF Connector: N-Type Male with hexagon coupling nut
Key Features
- True RMS detection across signal bandwidth for reliable readings on any waveform type
- Option 1 enables TDMA measurement capability and calibrates a diode pair for enhanced linearity across the full dynamic range
- Internal EEPROM stores frequency-, power-, and temperature-dependent calibration data for automatic meter configuration
- Precision N-Type connector rated for standard torque wrench attachment
Typical Applications Broadband power measurement of modulated RF signals in wireless communications testing, including 3G/4G protocols and OFDM waveforms. Suitable for CW and multi-tone signal characterization across X-band and lower microwave frequencies.
Compatibility & Integration Connects directly to Anritsu ML24xxA/B, ML2480A/B, and ML2490A power meters. Requires ML2407A/08A and ML2437A/38A meter firmware revision 3.10 or higher. Integrates with PowerSuite software on Windows 95 or higher via GPIB or RS232 for trace viewing and data logging.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 18 GHz | Power Range (dBm): '-60 dBm to +20 dBm |
Anritsu MA2482D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2482D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2482D price
This Anritsu MA2482D is listed at $1,430. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2482D calibration cost
NIST-traceable calibration for the Anritsu MA2482D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →