Anritsu MA2482D Universal Sensor, 10MHz to 18GHz

Anritsu RF Power Sensors. Frequency Range: 10 MHz to 18 GHz, Dynamic Range: 80 dB (six measurement ranges), Accuracy: <.

Model
Anritsu MA2482D
Calibration
Available on request
Price · starting from
$1,430
Status
In stock
RFQ ref
MA2482D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MA2482D is a true RMS power sensor engineered for broadband RF measurement across 10 MHz to 18 GHz. Its triple-diode architecture operates in the square-law region to deliver accurate average power readings of CW, multi-tone, and modulated waveforms - including 3G, 4G, and OFDM signals - independent of bandwidth. The 80 dB dynamic range spans six measurement ranges for versatile laboratory and production applications.


Technical Specifications



  • Frequency Range: 10 MHz to 18 GHz

  • Dynamic Range: 80 dB (six measurement ranges)

  • Power Measurement Range: –60 dBm to +20 dBm

  • Sensor Linearity: 3% (–60 to +20 dBm, 10 MHz to 18 GHz); 1.8% CW with Option 1

  • Rise Time: <0.004 ms (Option 1 only)

  • Temperature Accuracy: <1% (15°C to 35°C)

  • Maximum Measurable Power: 100 mW

  • VSWR: - <1.17 (10–150 MHz) - <1.12 (150 MHz–2 GHz) - <1.22 (2–12.4 GHz) - <1.25 (12.4–18 GHz)

  • RF Connector: N-Type Male with hexagon coupling nut


Key Features



  • True RMS detection across signal bandwidth for reliable readings on any waveform type

  • Option 1 enables TDMA measurement capability and calibrates a diode pair for enhanced linearity across the full dynamic range

  • Internal EEPROM stores frequency-, power-, and temperature-dependent calibration data for automatic meter configuration

  • Precision N-Type connector rated for standard torque wrench attachment


Typical Applications Broadband power measurement of modulated RF signals in wireless communications testing, including 3G/4G protocols and OFDM waveforms. Suitable for CW and multi-tone signal characterization across X-band and lower microwave frequencies.


Compatibility & Integration Connects directly to Anritsu ML24xxA/B, ML2480A/B, and ML2490A power meters. Requires ML2407A/08A and ML2437A/38A meter firmware revision 3.10 or higher. Integrates with PowerSuite software on Windows 95 or higher via GPIB or RS232 for trace viewing and data logging.

Specifications

ParameterValue
Frequency Range10 MHz to 18 GHz | Power Range (dBm): '-60 dBm to +20 dBm

Anritsu MA2482D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2482D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu MA2482D price

This Anritsu MA2482D is listed at $1,430. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MA2482D calibration cost

NIST-traceable calibration for the Anritsu MA2482D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →