JDS Uniphase MAPA+2370200FP

JDS Uniphase Optical Attenuators. Resolution: ** 0.001 dB (reference specification).

Model
JDS Uniphase MAPA+2370200FP
Calibration
Available on request
Price
$2,400
Status
In stock
RFQ ref
MAPA+2370200FP
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase MAPA+2370200FP is a precision optical attenuator module designed for integration into the Multiple Application Platform (MAP) modular test system. This cassette-based attenuator manages optical signal power across a wide attenuation range, delivering the performance required for fiber optic communications and optical test environments. The unit operates as a hot-swappable component within MAP chassis configurations, enabling flexible signal conditioning for single-mode and multimode fiber applications.

Technical Specifications

Product Series: Multiple Application Platform (MAP)

Function: Precision Optical Attenuator

Attenuation Range: Wide range capability

Insertion Loss: Minimal specification

Return Loss: Excellent performance specification

Linearity: ±0.1 dB (reference specification)

Resolution: 0.001 dB (reference specification)

Fiber Compatibility: Single-mode and multimode optical fiber types

Connector Type: Standard optical connector interfaces

Key Features

Hot-swappable cassette design for rapid field reconfiguration

Precision attenuation control with fine resolution capability

Low insertion loss and high return loss performance

Support for multiple fiber types and connector standards

Compact form factor optimized for 19-inch and benchtop chassis mounting

Typical Applications

Signal power management in fiber optic communication systems

Optical signal conditioning and level adjustment

Transmission path loss compensation

Telecommunications and photonics test environments

Optical network characterization and validation

Compatibility & Integration The MAPA+2370200FP integrates into both the 19-inch 8-slot Master chassis (MAP+2M00) and the 9.5-inch 3-slot Benchtop chassis (MAP+2B00). The MAP system provides centralized control via 9-key keypad and color display, with remote communication through RS-232 and GPIB interfaces.

JDS Uniphase MAPA+2370200FP — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MAPA+2370200FP. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase MAPA+2370200FP faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase MAPA+2370200FP price

This JDS Uniphase MAPA+2370200FP is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase MAPA+2370200FP calibration cost

NIST-traceable calibration for the JDS Uniphase MAPA+2370200FP is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →