JDS Uniphase MAPS+1W73221FA
The JDS Uniphase MAPS+1W73221FA is a module designed for the MAPS platform, likely used in optical testing and measurement applications. It offers functionality related to signal processing or wavelength management within optical networks.
- Model
- JDS Uniphase MAPS+1W73221FA
- Calibration
- Available on request
- Price
- $2,200
- Status
- In stock
- RFQ ref
- MAPS+1W73221FA
This unit
The JDS Uniphase MAPS+1W73221FA is a hot-swappable instrumentation cassette for the MAP (Multiple Application Platform) modular test system. It integrates into either the 19-inch 8-slot Master or 9.5-inch 3-slot Benchtop chassis, enabling dynamic optical test and measurement configurations across research, design, and manufacturing applications. The cassette installs on a common backplane with automatic firmware-based identification, eliminating manual setup. The MAP platform hosts over 15 cassette types - including EDFA amplifiers, tunable filters, broadband sources, ASE sources, and attenuators - allowing rapid system reconfiguration without hardware redesign.
Technical Specifications Optical Bands
C-band and L-band operation across supported cassette modules Operating Environment
Storage temperature: −30 to 60 °C
Operating temperature: 0 to 50 °C
Humidity: < 80% RH (0 to 40 °C, non-condensing)
Maximum altitude: 2000 meters
Transient overvoltage category: II
Pollution degree: 2
Airflow: Front-to-back, maximum 15 cfm per fan
Key Features
Automatic cassette detection via dynamic firmware
Hot-swappable design for field reconfiguration
Color display and 9-key keypad interface
Remote communication ports for system automation
Modular architecture supporting diverse optical test scenarios
Compatible Cassette Modules The MAPS+1W73221FA platform accommodates:
EDFA cassettes (saturated output 14–21 dBm, noise figure as low as 3.3 dB, gain flatness < 1.4 dB)
Tunable bandpass filters (1420–1630 nm continuous tuning, 300 mW or 1000 mW input options)
ASE sources (flattened high power density, C-band or C+L-band)
Broadband sources: BBS1550 (1527–1568 nm C-band), BBS1590 (1565–1610 nm L-band), BBS1560 (C+L-band)
Attenuators (single-mode and multimode, multiple connector types, tap or power control options)
Integration The MAP platform includes dedicated power supply modules and supports both benchtop and rack-mount configurations. Automatic firmware identification eliminates recalibration during cassette swaps.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | 14 dBm to 21 dBm (EDFA saturated output) |
| noise figure as low as 3.3 dB | Wavelength Range | 1420 nm to 1630 nm (tunable filter) |
JDS Uniphase MAPS+1W73221FA — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MAPS+1W73221FA. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase MAPS+1W73221FA faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.
JDS Uniphase MAPS+1W73221FA price
This JDS Uniphase MAPS+1W73221FA is listed at $2,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase MAPS+1W73221FA calibration cost
NIST-traceable calibration for the JDS Uniphase MAPS+1W73221FA is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →