Stanford Research MPA120 Optimelt Automated Melting Point System

The Stanford Research Systems MPA120 is a miniature transimpedance preamplifier designed for amplifying small current signals. It offers selectable gain settings and a compact form factor for easy integration into various experimental setups. Ideal for applications requiring sensitive current measurements.

Model
Stanford Research Systems MPA120
Calibration
Available on request
Price
$1,250
Status
In stock
RFQ ref
MPA120
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems MPA120 Optimelt is a fully automated melting point determination system that analyzes up to three samples simultaneously using digital image processing and PID-controlled temperature ramping. The instrument identifies clear points and onset of melt with 0.1 °C resolution across a range up to 400 °C, delivering repeatable results compliant with Pharmacopeia and GLP standards. Its compact aluminum oven design, built-in magnification lens, and wide observation window with internal illumination enable precise sample viewing without manual intervention.


Technical Specifications



  • Temperature measurement: Platinum RTD sensor, 0.1 °C resolution, up to 400 °C

  • Temperature control: PID-controlled microprocessor ramping with selectable rates from 0.1 °C/min to 20 °C/min (1-2-5 sequence)

  • Sample capacity: Three simultaneous samples

  • Detection method: Digital image processing technology

  • Temperature tagging: Up to four individual temperatures per sample via front-panel buttons

  • Capillary tubes: 100-count pack included; 1.4–2.0 mm OD, 100 mm length recommended; 2–3 mm fill height

  • Display: 4-digit LED for results and status

  • Oven: Compact aluminum construction

  • Power: 90–264 VAC, 47–63 Hz, 125 W consumption

  • Dimensions: 7.5" W × 10" D × 8.5" H; 9 lbs

  • Operating environment: 0 °C to 40 °C, non-condensing


Key Features



  • Fully automated operation - no operator attendance required

  • PID temperature control for fast, repeatable warm-up and cool-down cycles

  • Field calibration using certified reference standards

  • Integrated magnification lens with wide observation window and internal illumination

  • GLP-compliant data handling and documentation


Typical Applications Quality control, pharmaceutical compliance testing, research and development.


Compatibility & Integration



  • USB interface for instrument control and data querying

  • RS-232 serial port for Epson-compatible dot-matrix printer output

Specifications

ParameterValue
Voltage / Current Range47–63 Hz, 90–264 VAC

Stanford Research Systems MPA120 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems MPA120. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Stanford Research Systems MPA120 faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.

Stanford Research Systems MPA120 price

This Stanford Research Systems MPA120 is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems MPA120 calibration cost

NIST-traceable calibration for the Stanford Research Systems MPA120 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →