Stanford Research CIS100 Gas Analyzers
Stanford Research Systems Laboratory Measurement Instruments. Resolution: Better than 0.1 amu.
- Model
- Stanford Research Systems CIS100
- Calibration
- Available on request
- Price
- $3,500
- Status
- In stock
- RFQ ref
- CIS100
This unit
The Stanford Research Systems CIS100 is a Closed Ion Source Gas Analyzer for precise quantitative gas composition measurement in laboratory and industrial environments. It combines a quadrupole mass spectrometer with an integrated CIS ionizer in a compact 2.75" Conflat® flange probe, enabling direct chamber connection for on-line process monitoring, gas purity verification, residual gas analysis, and leak detection without sample preparation or external ionizer modules.
Technical Specifications
- Mass Range: 100 amu
- Detection Limit: 1 ppm (electron multiplier), 10 ppm (Faraday cup), 1 × 10⁻¹² Torr
- Maximum Operating Pressure: 10 mTorr
- Resolution: Better than 0.1 amu
- Mass Stability: ±0.1 amu after 30 minutes
- Warm-up Time: Peak height ±2% after 3 minutes
- Power Requirement: 24 VDC @ 2.5 A (optional AC line module available)
- Computer Interface: RS-232C, 28,800 baud
- Physical: 6 lbs, compact probe design with integrated control unit
Key Features
- Gold-plated stainless steel ionizer reduces outgassing and resists reactive gases
- Tungsten filament tolerates corrosive environments including WF₆ and silane exposure
- Dual detector configuration: Faraday cup and continuous dynode electron multiplier
- Field-replaceable electron multiplier and filament for minimal downtime
- Windows-based software supports up to eight ECUs with real-time RGA analysis
- Programmable mass scale tuning, sensitivity calibration, and ionizer setup
- User-selectable output units: ppm, Torr, mbar, Pa, A
- Data export in ASCII format; image export as META files or clipboard
- Programmable alarms and electron multiplier gain adjustment
Typical Applications
- On-line process gas monitoring and closed-loop control
- Process gas purity verification at sub-ppm levels
- High-vacuum residual gas analysis
- Equipment leak detection and isolation
Compatibility & Integration Requires connection to a pumping system with minimum 40 L/s effective pumping speed and base pressure below 10⁻⁹ Torr. Optional O100TDP provides integrated turbo pump and diaphragm roughing pump for direct mounting.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 24 VDC @ 2.5 A |
Stanford Research Systems CIS100 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems CIS100. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Stanford Research Systems CIS100 faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.
Stanford Research Systems CIS100 price
This Stanford Research Systems CIS100 is listed at $3,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Stanford Research Systems CIS100 calibration cost
NIST-traceable calibration for the Stanford Research Systems CIS100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →