Anritsu MS4644A Vector Network Analyzer, 10 MHz – 40 GHz
The Anritsu MS4644A is a vector network analyzer that operates from 10 MHz to 40 GHz. It is used for testing and characterizing the performance of high-frequency electronic components and systems.
- Model
- Anritsu MS4644A
- Calibration
- Available on request
- Price
- $32,000
- RFQ ref
- MS4644A
This unit
The Anritsu MS4644A is a 2-port vector network analyzer spanning 10 MHz to 40 GHz, designed for RF, microwave, and millimeter-wave component and system characterization. It combines source, test set, and analyzer in a single platform with real-time measurement display on a front-panel touchscreen or external monitor. The instrument delivers up to 140 dB dynamic range, measurement speeds below 20 µs per point, and input noise floor of −115 dBm at 40 GHz.
It supports up to 100,000 data points with advanced time-domain analysis at 700 kHz frequency step resolution for low-pass mode measurements.
Technical Specifications
- Frequency Range: 10 MHz to 40 GHz
- Ports: 2
- Dynamic Range: Up to 140 dB (maximum); 100 dB typical at 70 GHz
- Measurement Speed: Less than 20 µs per point (fastest swept synthesized); 20 µs per point typical (25,000 points with ALC, display, locking, and correction enabled)
- Output Power: Up to +13 dBm available; standard range +12 dBm to −25 dBm; optional ranges +11 dBm to −25 dBm or +10 dBm to −95 dBm
- Input Noise Floor: −115 dBm at 40 GHz
- Sensitivity: Greater than 80 dB
- Data Resolution: Up to 100,000 points; time-domain analysis at 700 kHz frequency step size (low-pass mode)
- Test Port Directivity, Source Match, Load Match: Up to 50 dB characteristic performance
Key Features
- Single-unit integration of source, test set, and analyzer
- Real-time touchscreen display with external monitor support
- Automatic one-button Precision AutoCal calibration system
- Active device measurements including single and multi-frequency gain compression
- Internal bias tees with two or four step attenuators for extended power range control
- Load-pull capabilities for linear and nonlinear amplifiers
- Swept power and I-V curve analysis software
Typical Applications
- Active device characterization and modeling
- Amplifier design and optimization
- Component S-parameter measurements
- Nonlinear device testing
Compatibility & Integration
- Interfaces: LAN, USB, GPIB, RS232C
- Display: Screen captures exportable in standard graphic formats
- Part of Anritsu VectorStar family platform
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 40 GHz | Power Range (dBm): '+12 dBm to −25 dBm (standard) |
Anritsu MS4644A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS4644A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MS4644A price
This Anritsu MS4644A is listed at $32,000. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS4644A calibration cost
NIST-traceable calibration for the Anritsu MS4644A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →