Anritsu MS9702B – Optical Spectrum Analyzer

Anritsu Optical Spectrum Analyzers. Dynamic Range: ** Up to 70 dB, Sensitivity: ** –90 dBm (guaranteed), Accuracy: ** ±0.1 nm (1530–1570 nm with 0.5–1 nm resolu.

Model
Anritsu MS9702B
Calibration
Available on request
Price
$2,400
Status
In stock
RFQ ref
MS9702B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9702B is a optical spectrum analyzer engineered for precise spectral characterization across visible and near-infrared wavelengths. It delivers advanced capabilities for research, development, manufacturing, and quality control environments, supporting detailed optical power measurement, wavelength analysis, and spectral evaluation of lasers, LEDs, and optical communication systems.

Technical Specifications

Wavelength Range: 0.6 µm to 1.75 µm

Dynamic Range: Up to 70 dB; 62 dB in normal measurement mode at 1 nm from peak; exceeds 70 dB in high-dynamic-range mode

Optical Reception Sensitivity: –90 dBm (guaranteed)

Wavelength Accuracy: ±0.1 nm (1530–1570 nm with 0.5–1 nm resolution, post-calibration with reference source)

Sweep Speed: 0.5 seconds typical (500 nm sweep width, normal mode, 10 kHz VBW)

Resolution Bandwidth: 0.1 nm to 1 nm selectable

Input Fiber Support: 50/62.5 µm core diameter

Power Requirements: 85–132 Vac or 170–250 Vac, 47.5–63 Hz; maximum 150 VA consumption

Key Features

6.4-inch color TFT-LCD display for real-time spectral visualization

Internal thermal printer for immediate hardcopy documentation

High dynamic range capability for SMSR measurements of DFB lasers and narrow-band optical filter evaluation

Detects signals down to –90 dBm for low-level optical signal analysis

Typical Applications

Side Mode Suppression Ratio (SMSR) characterization of DFB-LDs

Optical band-pass filter performance evaluation

Spectral analysis of laser sources and LEDs

Optical communication system component validation

Compatibility & Integration

GPIB and RS-232C interfaces for automated test system control

3.5-inch FDD storage (Windows) for measurement data archiving and transfer

Specifications

ParameterValue
Power Range (dBm)–90 dBm (sensitivity) | Voltage / Current Range: 47.5–63 Hz, 85–132 Vac or 170–250 Vac, max 150 VA | Wavelength Range: 0.6 µm to 1.75 µm

Frequently Asked Questions

What does the Anritsu MS9702B measure and what are its key specifications?
The MS9702B is a benchtop optical spectrum analyzer designed to characterize optical signals across a wavelength range of 0.6 µm to 1.75 µm, covering the critical C and L bands used in telecommunications. This instrument delivers up to 70 dB dynamic range with a guaranteed sensitivity of –90 dBm, making it suitable for WDM system verification, component testing, and signal quality assessment. Wavelength accuracy is specified at ±0.1 nm across the 1530–1570 nm region with 0.5–1 nm resolution capability.
What condition is this MS9702B in and what was verified before listing?
This unit is listed in used condition and has been functionally tested to confirm core measurement capabilities before sale. We verify power-on operation, display function, and basic wavelength response to ensure the instrument is field-ready. For customers requiring validated performance metrics across the full specification envelope, we offer calibration services separately, starting at $450.
What calibration options are available for the MS9702B and what does it cover?
We offer calibration services starting at $450, which typically covers wavelength accuracy verification and power measurement calibration across the operating range of the MS9702B. This service is performed separately from the instrument sale and ensures traceability to NIST standards for critical measurement applications. Contact us directly for turnaround time and detailed scope of work for your specific calibration requirements.
What interfaces and connectivity options does the MS9702B support?
The MS9702B features GPIB (IEEE 488) connectivity as its standard remote control interface, enabling integration into automated test systems and network monitoring setups. Power input is universal, accepting 47.5–63 Hz AC at 85–132 Vac or 170–250 Vac, with a maximum power draw of 150 VA. For detailed information about compatible software drivers, control libraries, and legacy-to-modern interface adapters, please contact our technical sales team.

Anritsu MS9702B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9702B. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9702B faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9702B price

This Anritsu MS9702B is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9702B calibration cost

NIST-traceable calibration for the Anritsu MS9702B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents