Anritsu MS9715M

Anritsu Optical Spectrum Analyzers. Model: MS9715M.

Model
Anritsu MS9715M
Calibration
Available on request
Price
$3,800
Status
In stock
RFQ ref
MS9715M
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9715M is a optical spectrum analyzer for precise characterization of optical devices and systems in R&D and manufacturing environments. It covers the C-band window (1460–1650 nm) with ±50 pm wavelength accuracy and ±0.4 dB level accuracy, delivering 53 dB dynamic range and 0.1 nm noise resolution. The instrument measures wavelength, optical power, OSNR, channel spacing, gain tilt, gain slope, and full spectrum profiles - essential for WDM system validation and DWDM network monitoring. An internal standard light source enables automatic wavelength calibration to compensate for temperature drift. Dual measurement modes support real-time spectrum analysis and long-term system surveillance, with capacity to log 1000 measurement sets per session. The zoom marker and guide spectrum features enable rapid identification of specific channels across dense wavelength grids. A standard LabVIEW driver facilitates remote control and automated test sequences. Windows-compatible floppy disk storage is built in for data archiving and transfer. The compact, lightweight design withstands operational vibration and shock. Operating window is 0–30 °C for specified measurement accuracy.

Specifications

ParameterValue
Wavelength Range1460 nm to 1650 nm

Frequently Asked Questions

What does the Anritsu MS9715M measure and what is its wavelength range?
The MS9715M is an optical spectrum analyzer designed to measure and analyze optical signals across the C-band window. It operates across a wavelength range of 1460 nm to 1650 nm, making it well-suited for characterizing DWDM systems, monitoring channel power, and troubleshooting optical network performance in telecommunications infrastructure.
What is the condition of this used Anritsu MS9715M and what was verified?
This unit is offered in used condition and has been cataloged for inventory at Aumictech. We recommend having the instrument calibrated before critical measurements to ensure traceability to NIST standards, particularly if it will be used in regulated or mission-critical applications.
What does calibration cover for the MS9715M and what is the cost?
Calibration service for this Anritsu optical spectrum analyzer is available separately and starts at $450. A full calibration typically verifies wavelength accuracy, power measurement linearity, and dynamic range performance across the 1460–1650 nm band, with detailed documentation provided upon completion.
What interfaces and connectivity options does the MS9715M support?
The MS9715M supports GPIB (IEEE 488) connectivity for remote control and data transfer to computers and automated test systems. Compatible software drivers and command sets are available from Anritsu, enabling integration into laboratory automation and network monitoring applications.

Anritsu MS9715M — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9715M. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9715M faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9715M price

This Anritsu MS9715M is listed at $3,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9715M calibration cost

NIST-traceable calibration for the Anritsu MS9715M is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →