Anritsu MS9720B – Optical Spectrum Analyzer

Anritsu Optical Spectrum Analyzers. Accuracy: ±20 pm (1530–1570 nm with reference source), Bandwidth: 0.03 nm, Dynamic range: 58 dB at 1 nm from signal.

Model
Anritsu MS9720B
Calibration
Available on request
Price
$3,800
Status
In stock
RFQ ref
MS9720B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9720B is a optical spectrum analyzer engineered for precise characterization of optical devices and WDM systems. Operating across the C-band, it delivers 58 dB dynamic range, -87 dBm sensitivity, and 0.03 nm minimum resolution bandwidth for detailed spectral analysis. Built-in acetylene calibration and an integrated SLD light source enable automated wavelength accuracy to ±20 pm, while multi-channel WDM analysis, NF measurement, PMD calculation, and SMSR capabilities address demanding R&D, manufacturing, and quality control workflows in optical communications.

Technical Specifications Wavelength Performance

Wavelength range: 1450 nm to 1650 nm

Wavelength accuracy: ±20 pm (1530–1570 nm with reference source)

Minimum resolution bandwidth: 0.03 nm

Dynamic range: 58 dB at 1 nm from signal

Optical sensitivity: -87 dBm

Maximum input level: +30 dBm (attenuator ON) Internal Light Source

Type: SLD (Super Luminescent Diode)

Output spectrum: 1450 nm to 1650 nm

Output level: -40 dBm minimum (1 nm RBW at 1550 nm) Measurement Functions

WDM analysis: Up to 128 channels with peak wavelength, level, and SNR per channel

NF measurement: ASE calculation using interpolation and level-fitting methods

PMD calculation: Fixed-analysis function for Polarization Mode Dispersion

SMSR measurement: Signal-to-Modulation Side-Band Ratio analysis System Interface

Wavelength calibration: Automatic via acetylene absorption spectrum

Monitor output: VGA connector

Communication: GPIB and RS-232C

Data storage: 3.5-inch floppy disk drive Environmental

Operating temperature: 0°C to +50°C

Storage temperature: –20°C to +60°C

Relative humidity: ≤90% (non-condensing)

Power: 85–132 Vac / 172–250 Vac, 47.5–63 Hz, 150 VA max

Dimensions: 320 (W) × 177 (H) × 350 (D) mm

Key Features

Automatic wavelength calibration eliminates manual reference procedures

Integrated SLD source simplifies benchtop deployment and reduces external component requirements

58 dB dynamic range resolves weak sidebands and noise floor analysis in complex spectra

Sub-0.1 nm resolution bandwidth enables detailed modulation sideband characterization

Typical Applications

WDM system development and channel verification across C-band

Optical amplifier performance assessment and ASE noise profiling

Laser and light source spectral purity validation

Transmission system commissioning and field troubleshooting

Compatibility & Integration GPIB and RS-232C interfaces enable automated test sequences and remote instrument control. Legacy data archival through floppy disk drive supports legacy workflows; measurement files integrate with instrument automation platforms via standard communication protocols.

Specifications

ParameterValue
Power Range (dBm)'-87 dBm to +30 dBm | Voltage / Current Range: 150 VA max, 47.5–63 Hz, 85–132 Vac / 172–250 Vac | Wavelength Range: 1450 nm to 1650 nm

Frequently Asked Questions

What does the Anritsu MS9720B measure, and what is its wavelength range?
The MS9720B is an optical spectrum analyzer designed to characterize optical signals across the C-band and L-band regions, covering wavelengths from 1450 nm to 1650 nm. It delivers wavelength accuracy of ±20 pm in the 1530–1570 nm window with a reference source, a 0.03 nm resolution bandwidth, and a 58 dB dynamic range at 1 nm offset from the signal peak. This instrument is widely used for DWDM system commissioning, fiber-optic network diagnostics, and optical component testing.
What is the condition of this used MS9720B, and what was verified?
This MS9720B is offered in used condition and has been functionally tested to confirm core measurement capabilities. We verify power range performance across its full span of −87 dBm to +30 dBm and confirm that wavelength and amplitude readings track within specification limits. Calibration is available separately through our service offerings if a fresh traceable certificate is required for your application.
What does calibration cover for the MS9720B, and how much does it cost?
Calibration service for the MS9720B begins at $450 and typically includes wavelength verification and power level accuracy across the operating range. We recommend recalibration if the instrument has not been serviced within two years or if your application requires traceable measurement certification. Turnaround time and scope details are available upon request when you contact our service team.
What interfaces and connectivity options does the MS9720B support?
The MS9720B features GPIB (IEEE-488) connectivity for remote instrument control and data transfer, making it compatible with automated test systems and standard laboratory software. The analyzer accepts 85–132 Vac or 172–250 Vac at 47.5–63 Hz with a maximum draw of 150 VA, and it integrates with Anritsu's proprietary measurement software via its parallel port. For detailed driver compatibility with your specific operating system or control architecture, contact our technical sales team.

Anritsu MS9720B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9720B. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9720B faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9720B price

This Anritsu MS9720B is listed at $3,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9720B calibration cost

NIST-traceable calibration for the Anritsu MS9720B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents