Yokogawa MV112-1-2-1D
Yokogawa Data Acquisition Systems (DAQ). Accuracy: ±(0.2% of reading + 4°C) for R.
- Model
- Yokogawa MV112-1-2-1D
- Calibration
- Available on request
- Price
- $1,500
- Status
- In stock
- RFQ ref
- MV112-1-2-1D
This unit
The Yokogawa MV112-1-2-1D is a 12-channel portable data acquisition unit within the MV100 MobileCorder series, engineered for real-time measurement and logging of mixed sensor inputs. The system accepts DC voltages, thermocouples, RTDs, and digital inputs on a single platform, with data displayed on a 5.5-inch wide-viewing-angle color LCD. Modular architecture enables flexible channel configuration for diverse industrial and laboratory applications requiring synchronized multi-parameter acquisition.
Technical Specifications
Measurement Channels & Performance- 12 measurement channels with simultaneous computation support (up to 12 channels)
- Measurement interval: 1 second standard; 2 seconds at 100 ms A/D integration time
- A/D integration time: 1.67 ms in fast sampling mode
- Thermocouple accuracy: ±(0.2% of reading + 4°C) for R, S, and B types
- Standard test conditions: 23 ±2°C, 55 ±10% RH, 50/60 Hz ±1% supply frequency, 30-minute minimum warm-up Data Storage & Formats
- Internal flash memory: 80 MB or 200 MB options
- CompactFlash card and USB memory support on compatible configurations
- Binary and text format save options to external media
- Event data, manual samples, time-series calculations, and report data logging Electrical Requirements
- AC supply: 90–132 VAC or 180–250 VAC
- Frequency: 50/60 Hz ±1%
Key Features
- Free mode and trigger-based acquisition (alarm, external contact, time, calculated data thresholds)
- Pre-trigger functionality for event capture
- 5.5-inch color LCD with wide viewing angle for on-site monitoring
- Mixed-input architecture supports voltage, thermocouple, RTD, and digital sensor types simultaneously
Typical Applications Temperature monitoring networks, multi-point voltage data logging, industrial process validation, equipment thermal analysis, and field-deployable data acquisition where portability and channel density are critical.
Compatibility & Integration CompactFlash memory cards and USB media (model-dependent) enable field data transfer. Binary format supports high-speed logging; text format facilitates downstream software integration and analysis workflows.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 180–250 VAC |
Yokogawa MV112-1-2-1D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Yokogawa MV112-1-2-1D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Yokogawa MV112-1-2-1D price
This Yokogawa MV112-1-2-1D is listed at $1,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Yokogawa MV112-1-2-1D calibration cost
NIST-traceable calibration for the Yokogawa MV112-1-2-1D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →