DWYEROMEGA / OMEGA OMB-DAQ-56 Personal DAQ USB Data Acquisition Module
Dwyer/Omega Data Acquisition Systems (DAQ). Current: 120 dB @ 60 Hz, Channel: to-channel crosstalk: <, Accuracy: ±0.5°C.
- Model
- Dwyer/Omega OMB-DAQ-56
- Calibration
- Available on request
- Price
- $650
- Status
- In stock
- RFQ ref
- OMB-DAQ-56
This unit
The OMB-DAQ-56 is a USB-powered personal data acquisition module engineered for portable signal capture and real-world measurement tasks. Built around a 22-bit A/D converter, It has 20 single-ended and 10 differential analog input channels within a compact form factor. Direct thermocouple measurement with integrated cold junction compensation supports eight industry-standard thermocouple types across temperature ranges from -200°C to +1400°C. Powered exclusively from the USB bus, the module requires no external power supplies and communicates via high-speed USB up to 5 m from the host PC. Scalability is inherent - up to 100 modules cascade through USB hubs to deliver 8000 total measurement channels from a single computer.
Technical Specifications Analog Input
22-bit A/D converter resolution
20 single-ended input channels
10 differential input channels
Programmable voltage ranges: ±31 mV to ±20 V full scale
Input resistance: >10 MΩ (single-ended), >20 MΩ (differential)
Bias current: 120 dB @ 60 Hz
Channel-to-channel crosstalk: <-120 dB (DC to 100 Hz) Thermocouple Measurement
Cold junction compensation accuracy: ±0.5°C
Type J: -100 to 700°C, ±1.1°C
Type K: -200 to 1200°C, ±1.2°C
Type T: -100 to 400°C, ±1.1°C
Type E: -100 to 500°C, ±1.0°C
Type R: -400 to 1400°C, ±2.5°C
Type S: 400 to 1400°C, ±2.6°C
Type B: 700 to 1400°C, ±3.3°C
Type N: -100 to 700°C, ±1.5°C Interface & Power
USB connectivity; bus-powered operation
Optional external supply: 6 to 16 Vdc when using bus-powered hubs
Maximum cable distance: 5 m (16.4 feet)
Multi-module capacity: up to 100 modules per PC, 8000 total channels
Key Features
Doubles the I/O capacity of the OMB-DAQ-55 in identical physical dimensions
Direct thermocouple support eliminates external signal conditioning
High input impedance and low bias current minimize loading effects
Exceptional channel isolation and common-mode rejection
Zero external power infrastructure required
Typical Applications
Industrial temperature monitoring and data logging
Multi-point voltage acquisition and transducer interfacing
Portable environmental and thermal testing
Research instrumentation requiring flexible channel expansion
Field diagnostics and system validation
Compatibility & Integration The module operates as a USB device requiring only driver software and standard hub infrastructure. Cascading up to 100 units through commercial USB hubs eliminates the need for specialized expansion chassis or external power distribution systems.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±31 mV to ±20 V (programmable ranges), 6 to 16 Vdc (optional external supply) |
Dwyer/Omega OMB-DAQ-56 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Dwyer/Omega OMB-DAQ-56. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Dwyer/Omega OMB-DAQ-56 price
This Dwyer/Omega OMB-DAQ-56 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Dwyer/Omega OMB-DAQ-56 calibration cost
NIST-traceable calibration for the Dwyer/Omega OMB-DAQ-56 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →