IFR Aeroflex PSD60-2R Fuel Quantity Test Set
IFR Aeroflex Calibration Equipment. Resolution: 0.01 pF (0–199.99 pF), Accuracy: ±0.1% of reading or 0.05 pF, Accuracy: ±2% of reading or 0.1 Ω.
- Model
- IFR Aeroflex PSD60-2R
- Calibration
- Available on request
- Price
- $3,470
- Status
- In stock
- RFQ ref
- PSD60-2R
This unit
The IFR Aeroflex PSD60-2R Fuel Quantity Test Set is a portable, battery-powered instrument for testing and calibrating aircraft AC capacitance fuel quantity indication systems. It performs on-aircraft or bench testing with precise measurement and simulation of capacitance values, resistance across eight ranges, and distance-to-fault diagnostics. The unit measures total tank capacitance, individual tank units, and compensators while simulating capacitance for indicator calibration and dry calibration procedures.
Technical Specifications
Capacitance Measurement- Range: 0.00 to 19,999 pF (three ranges); Extended Mode A: 0 to 39.99 KpF
- Resolution: 0.01 pF (0–199.99 pF); 0.1 pF (200.0–1,999.9 pF); 1 pF (2,000–19,999 pF)
- Accuracy: ±0.1% of reading or 0.05 pF, whichever is greater, from −25°C to +55°C Resistance Measurement
- Range: 0.00 Ω to 1,999 MΩ across eight ranges; optional range to 19,999 MΩ
- Accuracy: ±2% of reading or 0.1 Ω, whichever is greater, from −25°C to +55°C Distance-to-Fault (DTF) Measurement
- Range: 0.00 to 19,999 pF (1 pF resolution); 20.00 K to 39.99 K pF (10 pF resolution)
- Accuracy: ±0.1% of reading or 2 pF, whichever is greater Capacitance Simulation
- Tank Unit Simulator: 10 to 9,990 pF with infinite resolution
- Compensator Simulator: 10 to 990 pF with infinite resolution
Key Features
- Measures insulation resistance of tank units and aircraft harness
- Measures coax center conductor to shield for fault isolation
- DTF mode determines wire length or approximate distance to wire breaks
- 18 alkaline C-size non-rechargeable batteries with displayed charge status
- Four dedicated connectors (P1, P3, P4, J5) for tank units, compensators, and indicator circuits
Typical Applications
- Aircraft fuel system capacitance testing and troubleshooting
- Indicator calibration and compensator dry calibration
- Individual tank unit diagnostic measurement
- Harness integrity verification through insulation resistance testing
Compatibility & Integration Compatible with AD 98-20-40 and AD 99-03-04 compliant aircraft (Mod 6 and above). Dedicated interface cables required for full functionality.
IFR Aeroflex PSD60-2R — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the IFR Aeroflex PSD60-2R. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
IFR Aeroflex PSD60-2R price
This IFR Aeroflex PSD60-2R is listed at $3,470. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
IFR Aeroflex PSD60-2R calibration cost
NIST-traceable calibration for the IFR Aeroflex PSD60-2R is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →