Advantest Q82232 900nm-1650nm Optical Sensor

Advantest Optical Power Sensors. Power Range (dBm): -80 to +27 dBm, Wavelength Range: 900nm to 1650nm.

Model
Advantest Q82232
Calibration
Available on request
Price
$779
Status
In stock
RFQ ref
Q82232
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest Q82232 is a plug-in optical sensor module engineered for precision optical power measurement across the 900nm to 1650nm wavelength band. Built around a cooled InGaAs photodiode, it delivers measurement speeds up to 100 times/sec with noise performance of -94 dBm and dynamic range spanning -80 to +27 dBm. The sensor minimizes polarization dependence to 0.003 dBp-p or less, making it ideal for fiber-coupled optical testing, component characterization, and laser diode validation in both research and production environments.


Technical Specifications



  • Wavelength Range: 900nm – 1650nm

  • Power Measurement Range: -80 to +27 dBm

  • High Power Linearity: Up to +10 dBm

  • Measurement Speed: Up to 100 times/sec

  • Ranging Speed: 20 msec (minimum) to 500 msec (maximum)

  • Noise Level: -94 dBm

  • Polarization Dependence: 0.003 dBp-p or less

  • Accuracy at Calibration Point: ±2.5%

  • Accuracy (Broadband with Sensitivity Compensation): ±4.5%

  • Linearity: ±0.5%

  • Return Loss (Slant Polished Fiber): 50 dB or more

  • Return Loss (PC Polished with High-Return-Loss Adaptor): 45 dB or more (typical)

  • Sensor Element: Cooled InGaAs photodiode

  • Optical Input: 10 µm core diameter, NA 0.19 or less

  • Connectors: FC, SC, ST, MU, LC, and plug-in types

  • Internal Memory: 400 data points per channel (A and B)

  • Data Interface: GPIB at up to 100 times/sec


Key Features



  • Automatic sensitivity compensation based on entered wavelength

  • Dual measurement modes: CW (continuous) or chopped light (270Hz, 2kHz, 4kHz)

  • Independent dual-channel measurement capability

  • Low-noise design supports demanding production testing and metrology


Typical Applications



  • Optical fiber characterization and testing

  • Laser diode performance validation

  • Optical component power measurement

  • Production line quality control


Compatibility & Integration The Q82232 operates as a plug-in unit with compatible Advantest main units such as the Q8221. Pairs with the Q8163 Polarization Scrambler for high-speed, high-precision PDL measurements.

Specifications

ParameterValue
Power Range (dBm)'-80 to +27 dBm | Wavelength Range: 900nm to 1650nm

Advantest Q82232 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest Q82232. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest Q82232 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.

Advantest Q82232 price

This Advantest Q82232 is listed at $779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest Q82232 calibration cost

NIST-traceable calibration for the Advantest Q82232 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →