Advantest R3466/R3466N – Digital TV signal analyzer

The Advantest R3466/R3466N is a digital TV signal analyzer designed for evaluating the performance of digital television broadcasting systems and equipment. It supports various digital TV standards and provides comprehensive measurement capabilities for signal quality analysis, including modulation accuracy, MER, BER, and other key parameters. Ideal for R&D, manufacturing, and maintenance applications.

Model
Advantest R3466/R3466N
Calibration
Available on request
Price
$1,850
RFQ ref
R3466/R3466N
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R3466/R3466N is a digital TV signal analyzer engineered for evaluating performance across digital television broadcasting systems and equipment. It delivers real-time demodulation, multipath analysis, and modulation accuracy measurements across ISDB-T, ISDB-S, CATV 64QAM, and NTSC standards. The instrument excels in R&D, manufacturing, and broadcast maintenance environments where signal quality verification is critical.


Technical Specifications

Frequency Range:

  • R3466: 9 kHz to 3.3 GHz

  • R3466N: 9 kHz to 2.2 GHz Supported Standards:

  • ISDB-T (Terrestrial Digital Broadcasting)

  • ISDB-S (Satellite Digital Broadcasting)

  • CATV 64QAM

  • CS QPSK

  • NTSC Measurement Frequency Selection:

  • UHF, VHF, CATV, BS IF, CS IF, 110°CS IF channels

  • Arbitrary frequency selection Measurement Functions:

  • Field Strength

  • Bit Error Rate (BER)

  • Modulation Error Ratio (MER)

  • Carrier-to-Noise Ratio (CN)

  • Constellation Display

  • Delay Profile

  • Spectrum Mask Dynamic Range & Sensitivity:

  • Noise Level: 7 dBμV (−100 dBm) per 5.6 MHz with pre-amplifier ON

  • Third-order Intercept (TOI): +128 dBμV (+21 dBm)

  • Field Strength (ISDB-T, typical): 23 dBμVemf/5.6 MHz with pre-amplifier ON, S/N 10 dB Spectrum Analyzer Performance (with OPT.71):

  • Resolution Bandwidth: 1 Hz to 10 MHz


Key Features On-Air BER Measurement: Real-time null packet BER measurement during live ISDB-T transmission using Advantest's original on-air bit error measurement technology. TMCC Auto Detection: Automatic detection and configuration of ISDB-T transmission parameters eliminates manual setup. Delay Profile Analysis: Direct display of multipath interference via relative delay and level differences between direct and reflected waves on the time axis. Noise Margin & Equivalent CNR: Optional noise generator enables rapid assessment of system margin against noise degradation. Remote Operation: LAN-based remote control via Windows XP enables unattended monitoring at relay stations.


Compatibility & Integration Optional Modules:



  • OPT.10: Digital Input BER I/F

  • OPT.21: 5E-9/day X'tal Reference Source

  • OPT.22: 3E-10/day X'tal Reference Source

  • OPT.23: Rb Reference Source

  • OPT.60: ISDB-T BER Analysis (NM, Equivalent CNR, BER vs. CNR Measurement)

  • OPT.61: ISDB-T Interference Analysis

  • OPT.62: CATV 64QAM Analysis (ITU-T Rec. J.83 Annex-C)

  • OPT.71: RBW 1 Hz to 10 MHz

Specifications

ParameterValue
Frequency Range9 kHz to 3.3 GHz (R3466)
9 kHz to 2.2 GHz (R3466N) | Power Range (dBm)−100 dBm to +21 dBm

Advantest R3466/R3466N — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R3466/R3466N. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R3466/R3466N price

This Advantest R3466/R3466N is listed at $1,850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R3466/R3466N calibration cost

NIST-traceable calibration for the Advantest R3466/R3466N is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →