Advantest R4131E

The Advantest R4131E is a spectrum analyzer, known for its performance in signal analysis. It features a wide frequency range and high sensitivity, making it suitable for various applications, including signal monitoring, component testing, and electromagnetic interference measurement. Its user-friendly interface and comprehensive measurement functions ensure efficient spectrum analysis.

Model
Advantest R4131E
Calibration
Available on request
Price
$2,999
RFQ ref
R4131E
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R4131E is a spectrum analyzer designed for signal analysis from 9 kHz to 3.6 GHz. It delivers -140 dBm displayed average noise level and ±1.0 dB amplitude accuracy, making it suitable for EMI measurements, component testing, and signal monitoring in laboratory and field environments. The instrument combines flexible resolution bandwidth control (10 Hz to 3 MHz), wide amplitude range (-140 dBm to +30 dBm), and low local oscillator phase noise (-100 dBc/Hz at 10 kHz offset) with straightforward operation.


Technical Specifications

Frequency Domain

  • Frequency range: 9 kHz to 3.6 GHz

  • Resolution bandwidth: 10 Hz to 3 MHz (1-3 sequence)

  • Video bandwidth: 1 Hz to 3 MHz (1-3 sequence)

  • Frequency span: 10 Hz to 3.6 GHz

  • Frequency accuracy: ±1 × 10⁻⁶ ppm (crystal oven stabilized) Amplitude Domain

  • Amplitude range: -140 dBm to +30 dBm

  • Reference level: -80 dBm to +30 dBm

  • Amplitude accuracy: ±1.0 dB (typical, 25°C, 0 dB attenuation)

  • Displayed average noise level: -140 dBm (10 Hz RBW, 10 Hz VBW, preamplifier off)

  • Input attenuation: 0 dB to 70 dB, 1 dB steps

  • Maximum input: +30 dBm (0 dB attenuation); +20 dBm (≥10 dB attenuation)

  • Spurious response: -70 dBc or better (1 GHz, +10 dBm input)

  • Third-order intermodulation: -70 dBc or better (1 GHz, -20 dBm per tone) Performance

  • Local oscillator phase noise: -100 dBc/Hz (10 kHz offset, 1 GHz)

  • Sweep time: 50 ms to 2000 s

  • Triggering modes: Free run, video, external, line


Key Features



  • Average power, channel power, and adjacent channel power measurements

  • Occupied bandwidth and noise analysis

  • Carrier-to-noise ratio and phase jitter measurement

  • IEEE-488.2 GPIB interface for system integration

  • Type-N RF input connector (50 Ω)

  • External trigger and reference clock outputs


Electrical & Physical



  • Power: 100–240 V AC, 50/60 Hz, ~80 VA consumption

  • Dimensions: 420 × 177 × 450 mm; 17 kg

  • Operating temperature: 5°C to 35°C

  • Storage temperature: -20°C to 60°C


Compatibility & Integration IEEE-488.2 GPIB connectivity enables integration with data acquisition and control systems. Centronics printer/plotter interface supports documentation of measurements.

Specifications

ParameterValue
Frequency Range9 kHz to 3.6 GHz | Power Range (dBm): '-140 dBm to +30 dBm | Voltage / Current Range: 100–240 V AC, 50/60 Hz

Advantest R4131E — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R4131E. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R4131E price

This Advantest R4131E is listed at $2,999. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R4131E calibration cost

NIST-traceable calibration for the Advantest R4131E is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →