JDS Uniphase RM3 Backreflection Meter RM3750+1FA7 1310/1550

JDS Uniphase Fiber Characterization Systems. Power Range: 0 to -80 dBm, Accuracy: – ±0.4 dB for -60 dB to -67 dB readings, Accuracy: – ±0.1 dB between 0–3 dBm.

Model
JDS Uniphase RM3750+1FA7
Calibration
Available on request
Price
$2,930
Status
In stock
RFQ ref
RM3750+1FA7
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase RM3750+1FA7 is a dual-wavelength backreflection meter for single-mode fiber characterization. It measures backreflection, insertion loss, and optical power across 1310 nm and 1550 nm with direct display output and field portability via internal rechargeable battery. The instrument delivers backreflection accuracy to -75 dB and power measurement to -80 dBm, supporting component testing, system verification, and field service environments through an FC/APC connector interface.


Technical Specifications



  • Wavelengths: 1310 nm and 1550 nm

  • Fiber Type: Single-mode

  • Backreflection Range: 0 to -75 dB

  • Power Range: 0 to -80 dBm

  • Backreflection Accuracy: – ±0.4 dB for -60 dB to -67 dB readings – ±0.8 dB for -67 dB to -72 dB readings – ±1.5 dB for -72 dB to -75 dB readings – Accuracy in final 10 dB dependent on termination effectiveness

  • Power Accuracy: – ±0.1 dB between 0–3 dBm – ±0.1 dB between -35 dBm and -40 dBm – ±0.1 dB between -70 dBm and -80 dBm

  • Output Connector: FC/APC ultra-low backreflection

  • Light Sources: Dual internal laser sources at 1310 nm and 1550 nm


Key Features



  • Direct digital display for backreflection, power, and insertion loss readings

  • Internal rechargeable battery for portable field operation

  • Data logging via foot pedal to computer or serial printer (RS-232)

  • User-adjustable calibration for backreflection, loss, and power measurements

  • Extraneous backreflection compensation

  • Hybrid jumper compatibility for multi-connector testing

  • Annual recalibration by JDS Uniphase recommended


Typical Applications



  • Optical fiber component backreflection testing

  • Manufacturing quality control for fiber jumper assemblies

  • Single-output-port measurement in jumper manufacturing workflows

  • Optical system performance verification and acceptance testing

  • Research and development requiring precision optical measurements

  • Field service diagnostics and troubleshooting


Compatibility & Integration RS-232 port enables remote instrument control and automated data acquisition. FC/APC connector design accommodates hybrid jumpers for extended connector-type compatibility without degrading backreflection measurement performance.

Specifications

ParameterValue
Power Range (dBm)0 to -80 dBm | Wavelength Range: 1310 nm and 1550 nm

JDS Uniphase RM3750+1FA7 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase RM3750+1FA7. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

JDS Uniphase RM3750+1FA7 price

This JDS Uniphase RM3750+1FA7 is listed at $2,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase RM3750+1FA7 calibration cost

NIST-traceable calibration for the JDS Uniphase RM3750+1FA7 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents