Labworks Inc. SC-121

The Labworks Inc. SC-121 is a specialized device designed for [Intended Use]. It features [Key Feature 1], [Key Feature 2], and [Key Feature 3]. Ideal for [Specific Application], this unit ensures reliable and accurate results.

Model
Labworks Inc. SC-121
Calibration
Available on request
Price
$2,200
Status
In stock
RFQ ref
SC-121
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Labworks Inc. SC-121 is a sine servo controller purpose-built for sinusoidal vibration testing. Its dual microprocessor architecture delivers immediate control response and dynamic range of 70 dB minimum, while crystal-controlled digital signal synthesis and filtering ensure precise frequency generation and output stability across demanding test environments.

Technical Specifications Frequency Generation

2 to 6,553 Hz @ 0.1 Hz resolution (selectable via internal switch)

4 to 10,000 Hz @ 0.2 Hz resolution (selectable via internal switch) Vibration Feedback Analysis

Acceleration range: 0 to 99.9 g pk

Displacement range: 0 to 2.50 in pk-pk or 0 to 50.0 mm pk-pk

Input channels: 2 (independently selectable for control or feedback)

Calibration inputs: 10 or 100 mV/g

Variable inputs: 10 or 100 mV/g ±20% Output Specifications

Variable output sine voltage: 0 to 2.5 V rms @ 50 ohms

Constant output sine voltage: 0.60 V rms

Normalized acceleration outputs: 10 mV/g @ 50 ohms (both channels) Sweep and Control Parameters

Sweep type: Logarithmic

Operating modes: Manual, Continuous, or Single Sweep

Sweep rate: 0.5 to 8 octaves/min @ 0.5 octaves/min resolution

Servo speed: 3 ranges (microprocessor optimized and frequency dependent) Data Outputs

Acceleration log control: 2 Vdc/decade

Linear difference: 1.0 Vdc ±0.01 Vdc/% difference

Frequency log: 2 Vdc/decade

Sweep/pen lift logic: TTL, low during sweep Power and Environment

Input: 110 ±15 Vac or 220 ±30 Vac, 48–62 Hz

Operating temperature: 40 to 100 °F

Dimensions: 3.5" H × 19" W × 12" D (19-inch rack mount)

Key Features

Dual microprocessor design for optimized servo response

Selectable one or two-channel acceleration feedback for multi-accelerometer configurations

Difference output enabling transfer function determination and calibration verification

Internal non-volatile memory supporting up to three independent 1, 2, 3, or 4-level test profiles

Intuitive operator interface minimizing setup complexity

Typical Applications

Large head shaker and slip plate vibration control via multi-channel signal averaging

Sinusoidal sweep testing with programmable test profiles

Transfer function and fixture calibration characterization

Compatibility & Integration The SC-121 accepts dual accelerometer inputs with configurable feedback channels, allowing integration into complex shaker test systems where multiple measurement points require simultaneous monitoring or signal combination.

Specifications

ParameterValue
Frequency Range000 Hz @ 0.2 Hz resolution, 2 to 6, 553 Hz @ 0.1 Hz resolution
4 to 10 | Voltage / Current Range0 to 2.5 V rms output @ 50 ohms

Labworks Inc. SC-121 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Labworks Inc. SC-121. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Labworks Inc. SC-121 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Labworks Inc. SC-121 price

This Labworks Inc. SC-121 is listed at $2,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Labworks Inc. SC-121 calibration cost

NIST-traceable calibration for the Labworks Inc. SC-121 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents