The Rohde & Schwarz SMP04 is a microwave signal generator delivering precision frequency synthesis across 2 GHz to 40 GHz, with optional extension down to 10 MHz. It combines Direct Digital Synthesis technology with output power ranging from -20 dBm to +12 dBm (depending on frequency band) and exceptional spectral purity

SSB phase noise below –105 dBc/Hz at 10 GHz offset by 10 kHz. The instrument supports broadband modulation across AM, FM, Pulse, Phase, FSK, and ASK modes, with optional precision FM/ΦM and pulse generator capabilities.


Frequency setting time is <11 ms + 5 ms/GHz, and frequency resolution reaches 0.1 Hz. A built-in crystal reference provides 0.000001/yr timebase stability, with OCXO option available. Sweep functionality includes manual step, linear, and list modes.


The instrument stores up to 50 complete setup configurations and operates with 50 Ohm output impedance. Harmonics suppress to <–30 dBc below 1.8 GHz and non-harmonics to <–60 dBc up to 20 GHz. Target applications span microwave component characterization, radar and communication equipment testing, and EMC validation in development and production environments.


Technical Specifications



  • Frequency Range (Standard): 2 GHz to 40 GHz

  • Frequency Range (with Option SMP-B11): 10 MHz to 40 GHz

  • Frequency Resolution: 0.1 Hz

  • Frequency Setting Time: <11 ms + 5 ms/GHz

  • Output Power: +12 dBm (10 MHz to <2 GHz), +10 dBm (2 GHz to 18 GHz), +6 dBm (18 GHz to 20 GHz), +11 dBm (20 GHz to 33 GHz), +10 dBm (33 GHz to 40 GHz), +9 dBm (@40 GHz)

  • Minimum Output Power: -20 dBm

  • Output Level Resolution: 0.1 dB or 0.01 dB

  • Output Impedance: 50 Ohm

  • SSB Phase Noise: <–105 dBc/Hz at 10 GHz (10 kHz offset)

  • Harmonics: <–30 dBc (<+0 dBm) for f <1.8 GHz

  • Non-harmonics: <–60 dBc up to 20 GHz

  • Output Accuracy: <±0.9 dB at 0 dBm (10 MHz to 40 GHz with precision attenuator option)


Key Features



  • Direct Digital Synthesis frequency synthesis

  • Modulation modes: AM, FM (broadband to 5 MHz), Pulse, Phase (DC to 100 kHz), FSK (up to 1 MHz deviation), ASK

  • Optional precision FM/ΦM modulator (Option SM-B5) for modulation to 1 MHz

  • Optional pulse generator (Option SMP-B14)

  • Built-in crystal reference oscillator; optional OCXO (Option SMP-B1)

  • Timebase stability: 0.000001/yr

  • Memory: 50 stored instrument setups

  • Sweep modes: Step, Linear, List

  • Autorun control for synchronous multi-instrument operation


Typical Applications



  • Microwave component and subsystem development

  • Radar and communication system testing

  • EMC testing and validation

  • Production test routines


Compatibility & Integration 50 Ohm output interface. Autorun facility enables synchronized operation with complementary test equipment.

Specifications

ParameterValue
Frequency Range2 GHz to 40 GHz (standard)
10 MHz to 40 GHz (with Option SMP-B11) | Power Range (dBm)'-20 dBm to +12 dBm

Rohde &amp; Schwarz SMP04 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Rohde &amp; Schwarz SMP04. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Rohde &amp; Schwarz SMP04 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Rohde &amp; Schwarz SMP04 price

This Rohde &amp; Schwarz SMP04 is listed at $14,960. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Rohde &amp; Schwarz SMP04 calibration cost

NIST-traceable calibration for the Rohde &amp; Schwarz SMP04 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →