Stanford Research SR272
Stanford Research Systems Data Acquisition Systems (DAQ). Sample rate: up to 1100 samples/second, Channels: up to 7.
- Model
- Stanford Research Systems SR272
- Calibration
- Available on request
- Price
- $2,950
- Status
- In stock
- RFQ ref
- SR272
This unit
The SR272 is data acquisition software engineered for pulsed measurement systems using gated integrators and fast samplers. When paired with the SR245 Computer Interface module, it delivers a complete acquisition platform capable of simultaneous multi-channel scanning, automatic logging, and gate delay scans at rates up to 1100 samples/second. The software supports both single and multiple shots per bin with flexible triggering options - internal or external - and accommodates up to seven channels in parallel operation.
Data can be acquired using two distinct averaging strategies: scan averaging or multiple triggers per point averaging. The interface includes multiple graph windows with independent zoom and auto-scale controls, along with standard editing and clipboard operations. Windows-native help documentation is integrated throughout.
Technical Specifications
- Sample rate: up to 1100 samples/second
- Simultaneous channels: up to 7
- Gate delay: fixed or scanning
- Triggering: internal or external selectable
- Data storage: bitmaps, text files, CGM, MATLAB formats
Key Features
- Automatic scan logging with configurable bin architecture
- Gate delay scan capability for temporal characterization
- Dual averaging modes for noise reduction and signal enhancement
- Multi-graph display with independent scaling and zoom tools
- Direct editing, cut, and paste operations within the acquisition interface
Typical Applications Pulsed signal characterization in time-resolved spectroscopy, transient measurements, and gated detection experiments where precise temporal control and multi-point acquisition are required.
Compatibility & Integration Operates with SR250 Gated Integrator and SR255 Fast Sampler hardware. Requires SR245 Computer Interface module for system operation. Windows environment required.
Stanford Research Systems SR272 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems SR272. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Stanford Research Systems SR272 price
This Stanford Research Systems SR272 is listed at $2,950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Stanford Research Systems SR272 calibration cost
NIST-traceable calibration for the Stanford Research Systems SR272 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →