Advantest TQ8345 Optical Spectrum Analyzer

Advantest Optical Spectrum Analyzers. Resolution: Down to 0.001 nm for differentiation of closely sp, Accuracy: 5 ppm or ±0.1 nm.

Model
Advantest TQ8345
Calibration
Available on request
Price
$6,979
Status
In stock
RFQ ref
TQ8345
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest TQ8345 Optical Spectrum Analyzer delivers spectral characterization for optical components and systems. This benchtop instrument provides the precise measurement capabilities required for research, manufacturing, and quality control in telecommunications and photonics. Engineers and system integrators rely on it for detailed spectral analysis of optical signals across demanding applications.


Technical Specifications



  • Wavelength Coverage: 0.35 µm to 1.75 µm (visible through infrared spectrum)

  • Spectral Resolution: Down to 0.001 nm for differentiation of closely spaced spectral lines

  • Measurement Accuracy: 5 ppm or ±0.1 nm

  • Measurement Speed: Fast acquisition optimized for manufacturing throughput


Key Features



  • High-resolution spectral analysis enabling precise component characterization

  • Fast measurement cycles for efficient production testing

  • User-friendly interface for streamlined operation and data analysis

  • GPIB interface for automated control and integration into test systems

  • NIST-traceable calibration services ensuring measurement integrity and regulatory compliance


Typical Applications



  • Optical component characterization in R&D environments

  • Manufacturing quality control and throughput verification

  • Telecommunications and photonics system validation

  • Signal integrity and spectral purity assessment


Compatibility & Integration Standard GPIB connectivity enables straightforward integration into automated test systems, allowing remote instrument control and data logging for systematic quality assurance workflows.

Specifications

ParameterValue
Wavelength Range0.35 µm to 1.75 µm

Frequently Asked Questions

What does the Advantest TQ8345 measure and what is its wavelength range?
The Advantest TQ8345 is an optical spectrum analyzer designed to measure and characterize optical signals across the ultraviolet to near-infrared spectrum. It covers a wavelength range from 0.35 µm to 1.75 µm, making it suitable for telecommunications, component testing, and laser characterization applications. The instrument delivers resolution down to 0.001 nm, allowing you to differentiate closely spaced spectral features with high precision and accuracy of 5 ppm or ±0.1 nm.
What is the condition of this used Advantest TQ8345, and what was verified?
This is a used Advantest TQ8345 offered in working condition. We verify basic functionality and optical performance before listing to ensure the unit operates as specified. Calibration status and detailed service history are available upon request, and we offer calibration services separately to bring the instrument to traceable standards if needed.
What does calibration cover for the TQ8345, and what is the cost?
Calibration for the TQ8345 covers wavelength accuracy, resolution verification, and absolute power reference alignment across the specified operating range. We provide calibration services starting at $450, which establishes traceability to NIST standards and ensures measurement accuracy meets the 5 ppm specification. Turnaround time and detailed scope are confirmed during the calibration request process.
What interfaces and software compatibility does the TQ8345 support?
The TQ8345 features GPIB (IEEE-488) connectivity as its primary interface for remote control and automated measurement routines. The instrument is compatible with standard optical spectrum analyzer control software and legacy test automation environments. Specific driver requirements and software version compatibility should be confirmed with our technical team, as they depend on your host system and application requirements.

Advantest TQ8345 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest TQ8345. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest TQ8345 faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Advantest TQ8345 price

This Advantest TQ8345 is listed at $6,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest TQ8345 calibration cost

NIST-traceable calibration for the Advantest TQ8345 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →