Advantest TR5823 Universal counter
The Advantest TR5823 is a universal counter designed for a wide range of frequency, time, and signal analysis applications. It offers high resolution and accuracy, making it suitable for research, development, and production testing. Its versatile input channels and measurement functions provide comprehensive testing capabilities.
- Model
- Advantest TR5823
- Calibration
- Available on request
- Price
- $679
- Status
- In stock
- RFQ ref
- TR5823
This unit
The Advantest TR5823 Universal Counter delivers precision frequency, period, and time interval measurements across a 1 mHz to 1300 MHz range. This instrument employs three independent measurement methods - reciprocal, direct, and prescale - to maintain accuracy from sub-hertz to microwave frequencies. Designed for R&D, production test, and signal analysis environments, it combines fast measurement throughput with exceptional time base stability and optional GPIB/BCD interfaces for automated system integration.
Technical Specifications
Frequency Measurement- Channel A (10 Hz to 120 MHz): Direct method
- Channel B (1 mHz to 50 MHz): Reciprocal method
- Channel C (100 MHz to 1300 MHz): Prescale method
- Maximum frequency: 1300 MHz
- Minimum frequency: 1 mHz Period & Time Interval
- Period range: 20 ns to 1000 s
- Time interval range: 200 ns to 1000 s Frequency Ratio & Totalization
- Range: DC to 50 MHz Input Channels
- Channel 1: 100 mHz to 1300 MHz, 25 mV sensitivity, 1 MΩ impedance, AC/DC coupling
- Channel 2: 1000 Hz to 50 MHz, 25 mV sensitivity, 50 Ω impedance, AC/DC coupling
- Maximum input voltage (Channel 1): 25 mV Time Base
- Stability: 0.0000005/month
- Temperature coefficient: ±1 × 10⁻⁷ (0°C to +40°C)
- External reference: 10 MHz Measurement Throughput: 0.05 s
Key Features
- Multiple measurement methods eliminate frequency-dependent errors across the entire operating range
- Burst signal measurement capability with masking and offset functions
- Autotrigger mode for autonomous operation
- Self-check function for internal diagnostics
- Measurement throughput of 50 ms supports high-speed production test environments
Typical Applications Frequency characterization of RF components and subsystems; period and timing analysis in digital circuits; signal integrity verification; oscillator stability testing; and production acceptance testing across DC through microwave frequencies.
Compatibility & Integration Optional GPIB interface enables automated measurement and remote control within automated test systems. BCD output available for legacy equipment integration. Compatible with the TR1644 Calculation Unit for post-measurement data processing. Physical
Dimensions: 24 × 18 × 16 in
Weight: 25 lbs
Requires horizontal operation with 10 cm minimum clearance
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 mHz to 1300 MHz | Voltage / Current Range: 25 mV |
Advantest TR5823 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest TR5823. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest TR5823 price
This Advantest TR5823 is listed at $679. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest TR5823 calibration cost
NIST-traceable calibration for the Advantest TR5823 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →