Santec TSL210 Tunable Laser

The Santec TSL-210 is a tunable laser source renowned for its precision and stability in optical testing applications. It delivers accurate wavelength control and stable output power, making it suitable for characterizing optical components and systems.

Model
Santec TSL210
Calibration
Available on request
Price
$1,550
Status
In stock
RFQ ref
TSL210
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Santec TSL-210 is a tunable laser source engineered for precision optical testing across telecommunications and photonics applications. It delivers selectable wavelength windows spanning 1260 to 1650 nm with 0.01 nm resolution, 0.1 nm accuracy, and 0.05 nm repeatability. Output power typically exceeds 8 mW with 8% accuracy and 0.2 dB flatness.


The instrument combines fast wavelength tuning at 170 ms/nm with variable coherence control, adjustable linewidth from 1 to 500 MHz, and an optional tracking filter for ASE noise suppression. High-power configurations and a pulse variant (30 ps duration, 2.5 GHz repetition rate) extend utility across demanding R&D and production environments.


Technical Specifications

Wavelength Tuning

  • Range: Selectable windows 1260–1650 nm; TSL-210F offers continuous 1260–1630 nm (370 nm)

  • Tuning bandwidth: 80–100 nm per window; 370 nm for TSL-210F

  • Resolution: 0.01 nm (0.001 nm with fine tuning)

  • Accuracy: 0.1 nm

  • Repeatability: 0.05 nm (n=50, center wavelength)

  • Stability: 0.01 nm over 1 hour (center wavelength)

  • Fine tuning: 10 GHz or 0.08 nm typical

  • Tuning speed: 170 ms/nm Output Power

  • Maximum: >8 mW typical; >10 mW available in select configurations

  • High-power option: Reduces to 80% of specification with integrated filter

  • Accuracy: 8%

  • Repeatability: 0.01 dB (n=50, +6 dBm)

  • Stability: 0.01 dB over 1 hour (+6 dBm)

  • Flatness: 0.2 dB (+6 dBm) Spectral Characteristics

  • Linewidth: Maximum 1 MHz (coherence control OFF); 1–500 MHz adjustable (coherence control ON)

  • ASE noise: Optional tracking filter available for high SNR Modulation

  • Range: 0–10 kHz at −3 dBm

  • High-frequency modulation supported Pulse Variant (TSL-210)

  • Duration: 80 nm across full tuning band


Key Features



  • Fully variable coherence control as standard

  • Multiple selectable wavelength windows or continuous 370 nm tuning

  • Integrated tracking filter option for reduced ASE noise

  • High-power output configurations available

  • Sub-nanosecond pulse operation with GHz repetition rates


Typical Applications



  • Component characterization and wavelength-dependent testing

  • Optical filter and DWDM system validation

  • Research across C-, L-, and extended bands

  • Production wavelength verification and signal-to-noise ratio assessment


Compatibility & Integration The TSL-210 supports high-frequency modulation with configurable input terminals and level requirements detailed in operation documentation.

Specifications

ParameterValue
Power Range (dBm)>8 mW typical output (>10 mW available in select configurations) | Wavelength Range: 1260 nm to 1650 nm (selectable windows)
TSL-210F1260 nm to 1630 nm continuous

Santec TSL210 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Santec TSL210. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Santec TSL210 faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.

Santec TSL210 price

This Santec TSL210 is listed at $1,550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Santec TSL210 calibration cost

NIST-traceable calibration for the Santec TSL210 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents