Advantest U3741 9kHz to 3GHz Spectrum Analyzer
Advantest Spectrum Analyzers. Frequency Range: 9 kHz to 3 GHz, Power Range (dBm): -140 to +40 dBm (reference level); -135 dBm displayed average noise level (1 GHz, pre-amp on), Voltage / Current Range: ±50 VDC (DC input maximum).
- Model
- Advantest U3741
- Calibration
- Available on request
- Price
- $3,979
- RFQ ref
- U3741
This unit
The Advantest U3741 is a 9 kHz to 3 GHz spectrum analyzer engineered for signal analysis, component testing, and electromagnetic compatibility (EMC) measurements. It delivers high sensitivity with a displayed average noise level of −135 dBm at 1 GHz (pre-amplifier on) and maintains amplitude accuracy to ±1.0 dB across its full frequency range. The instrument supports multiple detection modes - normal, positive peak, negative peak, sample, RMS, and average - with configurable resolution bandwidth from 100 Hz to 1 MHz and video bandwidth spanning 10 Hz to 3 MHz.
Technical Specifications
Frequency & Amplitude- Frequency range: 9 kHz to 3 GHz
- Pre-amplifier active: 10 MHz to 3 GHz
- Frequency span: 5 kHz to full span; 1 kHz to full span with OPT.70
- Frequency span accuracy: <±1%
- Residual FM: <60 Hz peak-to-peak / 100 ms (internal reference)
- Measurement range: displayed average noise level to +30 dBm
- Maximum safe input: +30 dBm (attenuator ≥10 dB, pre-amp off); +13 dBm (pre-amp on)
- DC input maximum: ±50 VDC
- Input attenuator: 0 to 50 dB in 10 dB steps
- Reference level: −140 to +40 dBm Resolution & Sweep
- Resolution bandwidth: 100 Hz to 1 MHz; 30 Hz to 1 MHz with OPT.70/71
- RBW accuracy: <±12%
- Video bandwidth: 10 Hz to 3 MHz
- Sweep time: 20 ms to 1000 s (spectrum mode); 50 µs to 1000 s (zero span)
- Sweep time accuracy: <±2% (zero span)
- Sweep modes: continuous, single, gated Triggering & Calibration
- Trigger sources: free run, video, external, IF
- Calibration signal: 20 MHz at −20 dBm (75 Ω)
- Calibration accuracy: ±0.3 dB
- Amplitude accuracy (post-calibration): ±1.0 dB (9 kHz to 3 GHz); ±0.8 dB (10 MHz to 3 GHz)
Key Features
- Display modes include dBm, dBmV, dBµV, dBµVemf, dBpW, W, and V
- Optional low-frequency span capability down to 1 kHz with OPT.70
- Extended measurement range to 134 dBµV with OPT.15 installed
- User-friendly interface supports rapid measurement setup and analysis
Typical Applications
- Signal characterization across RF and microwave bands
- EMC and interference compliance testing
- Component and subsystem validation
- Spurious and harmonic content measurement
Compatibility & Integration The U3741 accepts multiple input scales and supports external and gated triggering for integration into automated test systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 3 GHz | Power Range (dBm): '-140 to +40 dBm (reference level) |
| -135 dBm displayed average noise level (1 GHz, pre-amp on) | Voltage / Current Range | ±50 VDC (DC input maximum) |
Advantest U3741 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest U3741. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest U3741 price
This Advantest U3741 is listed at $3,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest U3741 calibration cost
NIST-traceable calibration for the Advantest U3741 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →