Abaco Systems / VMIC VMIVME-1150-323 64-Bit Optically Coupled Digital Input Board

64-Bit Optically Coupled Digital Input Board

Model
Abaco Systems / VMIC VMIVME-1150-323
Calibration
Available on request
Price
$5,499
Status
In stock
RFQ ref
VMIVME-1150-323
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Abaco Systems / VMIC VMIVME-1150-323 is a 64-channel optically isolated digital input board for VMEbus systems. It acquires logic-level signals across a wide voltage range with 1,000 V sustained and 7,500 V pulsed isolation, making it suitable for industrial control, data acquisition, and signal monitoring in harsh electrical environments. The board supports 8-bit or 16-bit data transfers with individually addressable ports, configurable input polarity, and jumper-selectable filtering for noise rejection.


Technical Specifications



  • Channels: 64 optically coupled digital inputs

  • Input Voltage Range: 5 VDC to 48 VDC

  • Input Configuration: Voltage sourcing or current sinking; configurable for voltage input or contact closure

  • Data Polarity: Positive or negative true, field-selectable

  • Isolation: 1,000 V sustained; 7,500 V pulsed

  • Data Transfers: 8-bit or 16-bit modes supported

  • Addressing: Individually addressable 8-bit ports on 8- or 16-bit boundaries in short supervisory or nonprivileged I/O space

  • Board Address: DIP switch selectable; supported in any VMEbus slot except slot 1

  • Input Filtering: Jumper-selectable filtered input options

  • Form Factor: Standard VME double-height Eurocard (160 mm × 233.5 mm)

  • Power: +5 VDC @ 1.1 A typical, 2.2 A maximum

  • Operating Temperature: 0 °C to +55 °C

  • Storage Temperature: -40 °C to +85 °C

  • MTBF: 139,706 hours (MIL-HDBK-217F)


Key Features



  • Dual 64-pin DIN connectors for signal I/O

  • VMEbus electrical and mechanical compatibility

  • DTACK reply generation for decoded short supervisory or nonprivileged access

  • Drop-in replacement for legacy VMIVME-1150 models with software and cable compatibility


Typical Applications Industrial process control, data acquisition systems, machine monitoring, and equipment with mixed-signal sensing requirements where optical isolation is critical.


Compatibility & Integration Fully compatible with VMEbus architecture. Operates within any standard VME slot configuration except slot 1. Includes hardware reference manual and IOWorks integration documentation.

Specifications

ParameterValue
Voltage / Current Range2.2 A maximum, 5 VDC to 48 VDC input

Abaco Systems / VMIC VMIVME-1150-323 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Abaco Systems / VMIC VMIVME-1150-323. Calibration covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Abaco Systems / VMIC VMIVME-1150-323 faults: ESD-damaged input protection, failed driver ICs, connector pin damage. Most failures involve ESD-damaged input protection circuitry, failed logic driver ICs, or mechanical connector pin damage. Board-level component replacement is standard practice.

Abaco Systems / VMIC VMIVME-1150-323 price

This Abaco Systems / VMIC VMIVME-1150-323 is listed at $5,499. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Abaco Systems / VMIC VMIVME-1150-323 calibration cost

NIST-traceable calibration for the Abaco Systems / VMIC VMIVME-1150-323 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents