Abaco Systems / VMIC VMIVME-3128-000M01 Scanning 14-Bit A/D Converter Board

Abaco Systems / VMIC Data Acquisition Systems (DAQ). Voltage / Current Range: ±10 V, ±2.5 V, ±5 V, 0 to +10 V, 0 to +5 V, Resolution: 14-bit A/D conversion, Channels: 64 differential or single-ended inputs.

Model
Abaco Systems / VMIC VMIVME-3128-000M01
Calibration
Available on request
Price
$3,499
Status
In stock
RFQ ref
VMIVME-3128-000M01
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Abaco Systems / VMIC VMIVME-3128-000M01 is a VMEbus-compatible 14-bit analog-to-digital converter board engineered for high-speed data acquisition in demanding environments. This scanning A/D converter delivers precise analog signal digitization across up to 64 differential or single-ended input channels with program-selectable channel configurations. On-board dual-ported memory, interval timers, and programmable bus interrupters minimize host processor overhead while supporting multiple acquisition modes from continuous autoscanning to triggered burst capture.


Technical Specifications



  • Resolution: 14-bit A/D conversion

  • Input Channels: 64 differential or single-ended inputs; program-selectable scanning of 16, 32, 48, or 64 channels

  • Conversion Rate: 52 kHz to 58 kHz; 17 µs conversion cycle time (acquisition, conversion, and storage)

  • Channel Sample Rate (Maximum): 3.625 KSPS (58 KSPS ÷ minimum 16-channel scanning block)

  • Data Buffer: 1,024-word capacity; configurable as 16-word deep × 64 channels; selectable 16 to 1,024 data words in six 2:1 ratios

  • Programmable Gain Amplifier: Software-selectable gains of 1, 10, or 100; jumper-configurable for fixed or real-time per-channel control

  • A/D Voltage Ranges (Jumper-Selectable): 0 to +5 V, 0 to +10 V, ±2.5 V, ±5 V, ±10 V

  • Input Range: ±25 mV to ±10 V full-scale; overvoltage protected

  • Interval Timer: User-programmable up to 536 seconds; supports repetitive or single-shot modes


Key Features



  • Operating Modes: Autoscanning, single-channel random polling, timed burst (repetitive or single-shot), locally triggered burst, remotely triggered burst, and gain loading

  • VMEbus Compliance: DTB Slave, Interrupter (1 to 7), Requestor (DYN); ANSI/IEEE STD 1014-1987, IEC 821 and 297; A24/A16:D16/D8 address space support

  • Interrupts: Programmable VMEbus interrupts at buffer scan completion or after specified sample counts; dynamic interrupt vector control

  • Address Modes: Jumper-selectable short I/O A16 or standard A24 address space; supports supervisory/user privilege and data/program access


Typical Applications High-density multichannel data acquisition, industrial control systems, signal monitoring, and real-time embedded measurement requiring flexible gain control and triggered data capture.


Compatibility & Integration VMEbus systems requiring A/D conversion with minimal processor intervention; integrates with VMEbus backplane infrastructure supporting slave DTB operation and dynamic interrupt handling.

Specifications

ParameterValue
Voltage / Current Range±10 V, ±2.5 V, ±5 V, 0 to +10 V, 0 to +5 V

Abaco Systems / VMIC VMIVME-3128-000M01 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Abaco Systems / VMIC VMIVME-3128-000M01. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Abaco Systems / VMIC VMIVME-3128-000M01 price

This Abaco Systems / VMIC VMIVME-3128-000M01 is listed at $3,499. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Abaco Systems / VMIC VMIVME-3128-000M01 calibration cost

NIST-traceable calibration for the Abaco Systems / VMIC VMIVME-3128-000M01 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →