The Fluke/Wavetek/Datron 1362 is a 6.5 digit VXI multimeter module designed for high-precision measurements in automated test systems. It offers exceptional accuracy, resolution, and speed, making it suitable for demanding applications in calibration, metrology, and manufacturing test environments.

Model
Fluke/Wavetek/Datron 1362
Calibration
Available on request
Price
$1,450
Status
In stock
RFQ ref
1362
View cart

This unit

The Fluke/Wavetek/Datron 1362 is a VXIbus-compatible, message-based 6.5-digit digital multimeter module engineered for high-precision automated test systems. This single-slot, C-size VXI module (revision 1.4 conformant) delivers selectable resolution from 4.5 to 6.5 digits with read rates up to 1000 per second at 4.5 digits, scaling to 5 readings per second at 6.5 digits for DC voltage. Internal memory stores 1 to 1000 readings, decoupling measurement speed from system controller bandwidth. ## Technical Specifications Measurement Ranges & Resolution • DC Voltage: 100 mV to 300 V in decade steps; 100 nV resolution at 6.5 digits • AC Voltage (true RMS): 100 mV to 300 V in decade steps; 1 µV resolution at 5.5 digits • Resistance: selectable resolution from 4.5 to 6.5 digits • Optional modules: DC Current, AC Current (to 2 A with 5.5-digit resolution), and ratio measurements Performance • DCV accuracy (90 days, 23°C ± 5°C): 100 mV range ± (30 ppmR + 6 ppmFS); 1 V ± (20 ppmR + 3 ppmFS); 10 V ± (20 ppmR + 2 ppmFS); 100 V & 300 V ± (30 ppmR + 3 ppmFS) • ACV frequency response: 10 Hz–40 Hz ± (0.4 %R + 0.1 %FS); 40 Hz–3 kHz ± (0.08 %R + 0.03 %FS); 40 Hz–20 kHz ± (0.035 %R + 0.01 %FS); 20 kHz–50 kHz ± (0.1 %R + 0.02 %FS) • DCV input impedance: 10 GΩ (0.1 V–10 V); 10 MΩ (100 V & 300 V) • CMRR: >146 dB DC; >80 dB + NMRR at 1–60 Hz • NMRR: >54 dB at 50/60 Hz • Overvoltage protection: 300 V RMS all ranges Triggering & Control • Dual trigger sources: internal system trigger or external TTL level • Front-panel or VXI backplane trigger selection • Measurement-complete trigger capability • External trigger with programmable delay • Autocal feature for external calibration without cover removal Programming & Integration • IEEE-488.2 programmable (1362, 1362MT) • SCPI-compatible variants (1362S, 1362F) • MATE/CIIL support (1362MT) • VXI synchronous and asynchronous protocol compliance Operating Environment • Temperature range: 0°C to +50°C ## Key Features • High read rates up to 1000 per second enable fast data acquisition • Onboard 1000-reading buffer decouples measurement and readback timing • Selectable resolution optimizes speed/accuracy tradeoff • Multiple programming interfaces support diverse system architectures • Programmable external calibration maintains accuracy without module removal ## Typical Applications Automated production test, incoming inspection, environmental monitoring, precision component characterization, and integrated ATE systems requiring high-density multimeter modules. ## Compatibility & Integration VXI specification 1.4 conformance ensures interoperability with standard VXI controllers. IEEE-488.2, SCPI, and CIIL command support accommodate legacy and modern system architectures.

Specifications

ParameterValue
Frequency Range10 Hz to 50 kHz | Voltage / Current Range: 100 mV to 300 V DC/AC