Fluke / Wavetek / Datron 1362 6.5 Digit Multimeter VXI Module
The Fluke/Wavetek/Datron 1362 is a 6.5 digit VXI multimeter module designed for high-precision measurements in automated test systems. It offers exceptional accuracy, resolution, and speed, making it suitable for demanding applications in calibration, metrology, and manufacturing test environments.
- Model
- Fluke/Wavetek/Datron 1362
- Calibration
- Available on request
- Price
- $1,450
- Status
- In stock
- RFQ ref
- 1362
This unit
The Fluke/Wavetek/Datron 1362 is a VXIbus-compatible, message-based 6.5-digit digital multimeter module engineered for high-precision automated test systems. This single-slot, C-size VXI module (revision 1.4 conformant) delivers selectable resolution from 4.5 to 6.5 digits with read rates up to 1000 per second at 4.5 digits, scaling to 5 readings per second at 6.5 digits for DC voltage. Internal memory stores 1 to 1000 readings, decoupling measurement speed from system controller bandwidth.
Technical Specifications Measurement Ranges & Resolution
DC Voltage: 100 mV to 300 V in decade steps; 100 nV resolution at 6.5 digits
AC Voltage (true RMS): 100 mV to 300 V in decade steps; 1 µV resolution at 5.5 digits
Resistance: selectable resolution from 4.5 to 6.5 digits
Optional modules: DC Current, AC Current (to 2 A with 5.5-digit resolution), and ratio measurements Performance
DCV accuracy (90 days, 23°C ± 5°C): 100 mV range ± (30 ppmR + 6 ppmFS); 1 V ± (20 ppmR + 3 ppmFS); 10 V ± (20 ppmR + 2 ppmFS); 100 V & 300 V ± (30 ppmR + 3 ppmFS)
ACV frequency response: 10 Hz–40 Hz ± (0.4 %R + 0.1 %FS); 40 Hz–3 kHz ± (0.08 %R + 0.03 %FS); 40 Hz–20 kHz ± (0.035 %R + 0.01 %FS); 20 kHz–50 kHz ± (0.1 %R + 0.02 %FS)
DCV input impedance: 10 GΩ (0.1 V–10 V); 10 MΩ (100 V & 300 V)
CMRR: >146 dB DC; >80 dB + NMRR at 1–60 Hz
NMRR: >54 dB at 50/60 Hz
Overvoltage protection: 300 V RMS all ranges Triggering & Control
Dual trigger sources: internal system trigger or external TTL level
Front-panel or VXI backplane trigger selection
Measurement-complete trigger capability
External trigger with programmable delay
Autocal feature for external calibration without cover removal Programming & Integration
IEEE-488.2 programmable (1362, 1362MT)
SCPI-compatible variants (1362S, 1362F)
MATE/CIIL support (1362MT)
VXI synchronous and asynchronous protocol compliance Operating Environment
Temperature range: 0°C to +50°C
Key Features
High read rates up to 1000 per second enable fast data acquisition
Onboard 1000-reading buffer decouples measurement and readback timing
Selectable resolution optimizes speed/accuracy tradeoff
Multiple programming interfaces support diverse system architectures
Programmable external calibration maintains accuracy without module removal
Typical Applications Automated production test, incoming inspection, environmental monitoring, precision component characterization, and integrated ATE systems requiring high-density multimeter modules.
Compatibility & Integration VXI specification 1.4 conformance ensures interoperability with standard VXI controllers. IEEE-488.2, SCPI, and CIIL command support accommodate legacy and modern system architectures.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 Hz to 50 kHz | Voltage / Current Range: 100 mV to 300 V DC/AC |
Fluke/Wavetek/Datron 1362 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke/Wavetek/Datron 1362. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke/Wavetek/Datron 1362 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Fluke/Wavetek/Datron 1362 price
This Fluke/Wavetek/Datron 1362 is listed at $1,450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke/Wavetek/Datron 1362 calibration cost
NIST-traceable calibration for the Fluke/Wavetek/Datron 1362 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →