Keithley 179A

The Keithley 179A is a reliable 4 1/2 digit multimeter known for its accuracy and stability. It features a wide range of measurement capabilities including DC voltage, AC voltage, DC current, AC current, and resistance. Ideal for general purpose testing and troubleshooting in electronics and electrical engineering.

Model
Keithley 179A
Calibration
Available on request
Price
$165
Status
In stock
RFQ ref
179A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 179A is a 4½-digit True RMS digital multimeter engineered for precision measurement across DC voltage, AC voltage, DC current, AC current, and resistance. Built for laboratory and field deployment, it delivers waveform-insensitive AC measurements via TRMS technology and spans measurement ranges from 1 µV to 1000 V for voltage and 1 mΩ to 220 MΩ for resistance.

Technical Specifications Display & Interface

4½-digit LCD with backlight; 0.45-inch digit height

Polarity, function, range, and status indication

Overrange display: "OL"

Conversion rate: 3 readings/second Voltage Measurement

DC: 200 mV to 1200 V (5 ranges); ±0.04% accuracy; 10 MΩ input impedance; 1 µV resolution

AC (TRMS): Up to 100 kHz; ±(0.07% of reading + 2 counts); 3:1 crest factor; 2-second settling time Current Measurement

DC: 200 µA to 20 A (6 ranges); ±0.02% accuracy (up to 2 A); ±0.5% at 20 A; 1 nA resolution

AC (TRMS): Up to 15 A continuous, 20 A periodic; ±(0.07% of reading + 2 counts); 3:1 crest factor; 2-second settling time Resistance

Range: 1 mΩ to 220 MΩ (11 decades)

Accuracy: ±(0.01% of reading + 2 counts) on 200 Ω range

HI/LO Ohms modes: HI provides 2 V compliance for semiconductor activation; LO offers 200 mV compliance for in-circuit testing

1 kV protection on Ω input Performance

Warm-up time: 1 hour to rated accuracy

Temperature coefficient: ±(0.01% of reading + 0.2 digits)/°C

Key Features

Front-panel push-button range and function selection with automatic polarity

100-reading data storage with selectable rates from 3 readings/second to 1 reading/hour, plus manual trigger

Continuous min/max recording

Dual resistance modes for semiconductor and in-circuit applications

Typical Applications General-purpose electronics testing, troubleshooting, laboratory measurement, and field diagnostics where TRMS AC accuracy on non-sinusoidal waveforms is required.

Specifications

ParameterValue
Frequency RangeDC to 100 kHz (AC measurements) | Voltage / Current Range: DC voltage: 200 mV to 1200 V
AC voltage1 mV to 1000 V
DC current200 µA to 20 A
AC current1 mA to 20 A

Keithley 179A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 179A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 179A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 179A price

This Keithley 179A is listed at $165. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 179A calibration cost

NIST-traceable calibration for the Keithley 179A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents