Astronics / EADS / Racal 2251 VXI Counter Timer

Astronics / EADS / Racal VXI Modules. Resolution: Up to 9 digits per second at 1 GHz, Sensitivity: <, Resolution: 2.5 mV (manual mode).

Model
Astronics / EADS / Racal 2251
Calibration
Available on request
Price
$1,450
Status
In stock
RFQ ref
2251
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Astronics / EADS / Racal 2251 is a single-slot, C-size VXI counter timer module engineered for precision measurement applications requiring extensive arming and triggering control. Installed in a VXIbus-compatible mainframe and controlled remotely over VXIbus, it delivers frequency, period, time interval, pulse width, rise/fall time, frequency ratio, phase, and totalizing measurements across multiple input channels with nanosecond-level resolution.

Technical Specifications Form Factor & Control

Single-slot, C-size VXI module

VXIbus System Specification Revision 1.4 compatible

Remote VXIbus control only; no local control

NSN: 6625-01-371-8269 Frequency Measurement

Channel A: DC to 200 MHz

Channel B: DC to 160 MHz

Channel C (Option 41): 40 MHz to 1.3 GHz

Resolution: Up to 9 digits per second at 1 GHz; 10 nHz at 10 Hz in one second Time & Period Measurement

Period: 5 nS (Channel A), 6.25 nS (Channel B)

Time Interval: −2 ns to 1 × 10⁹ sec; 1 ns (single-shot), 100 ps (average mode)

Pulse Width: 5 ns to 20 ms Input Conditioning

Sensitivity: <100 MHz: 25 mVrms, 75 mVp-p

Input Voltage Range: ±5.1 V or ±42 V

Trigger Resolution: 2.5 mV (manual mode)

Low Pass Filters: 50 kHz per channel Measurement Functions

Frequency Ratio: Channel A/B; Channel C/B (Option 41, to 1.3 GHz)

Phase Measurement: Phase A relative to B; 0.10 to 360 degrees

Totalizing: Total A by B; manual totalize modes

Rise/Fall Time: Programmable trigger level −5.1 V to +5.1 V

Check Mode operation Accuracy & Performance

Accuracy: ± Resolution ± Timebase Error × Frequency

VXIbus CLK10: 100 ppm typ.

Typical Applications Frequency and period measurement; time interval and pulse width characterization; rise/fall time analysis; phase relationship determination; event counting and frequency ratio computation.

Compatibility & Integration Operates within VXIbus mainframe environments. No standalone operation.

Specifications

ParameterValue
Frequency Range30 Hz to 54 kHz | Voltage / Current Range: 20 mV to 300 V RMS

Astronics / EADS / Racal 2251 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 2251. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / EADS / Racal 2251 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / EADS / Racal 2251 price

This Astronics / EADS / Racal 2251 is listed at $1,450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / EADS / Racal 2251 calibration cost

NIST-traceable calibration for the Astronics / EADS / Racal 2251 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents