Agilent/Keysight 3400A
The Agilent/Keysight 3400A is a versatile function generator suitable for a wide range of testing and measurement applications. It delivers stable and precise waveforms. Ideal for education, research, and service applications where accurate signal generation is required.
- Model
- Agilent / Keysight 3400A
- Calibration
- Available on request
- Price
- $1,250
- Status
- In stock
- RFQ ref
- 3400A
This unit
The Agilent/Keysight 3400A is a true RMS voltmeter that measures AC voltage amplitudes across a 10 Hz to 10 MHz frequency range. It delivers accurate RMS readings for both sinusoidal and non-sinusoidal waveforms, making it essential for broadband noise characterization and signal amplitude verification in test environments where precision matters.
Technical Specifications
Measurement & Range- True RMS AC voltage measurement
- Voltage ranges: 1 mV to 300 V full scale
- dB range: -72 to +52 dBm (0 dBm = 1 mW into 600 Ω)
- Frequency response: 10 Hz to 10 MHz Accuracy
- ±5% of full scale (10 Hz to 50 Hz)
- ±1% of full scale (50 Hz to 1 MHz)
- ±2% of full scale (1 MHz to 2 MHz)
- ±3% of full scale (2 MHz to 3 MHz)
- ±5% of full scale (3 MHz to 10 MHz)
- Temperature coefficient: ±0.1% (0°C to 20°C and 30°C to 55°C) Input Characteristics
- Input impedance: 10 MΩ shunted by <50 pF (0.001 V to 0.3 V); 10 MΩ shunted by <20 pF (1.0 V to 300 V)
- AC coupled input
- Crest factor: Up to 10:1 at full scale; up to 100:1 at 10% of full scale
- Maximum continuous input: 500 V AC peak at 1 kHz; 600 V DC on all ranges
- AC overload protection: 30 dB above full scale or 800 V peak, whichever is less Output & Response
- DC output: 0 to 1 V DC proportional to deflection (10–100% full scale), max 1 mA, nominal source impedance 1000 Ω
- Output noise: <1 mV RMS
- Response time: <5 seconds to final value Power Requirements
- 115 or 230 V ±10%, 48 to 66 Hz, 15 VA maximum
Key Features
- Handles complex waveforms and broadband noise through true RMS conversion
- Wide dynamic range with frequency-dependent accuracy optimized for 50 Hz to 1 MHz operation
- Rear-panel DC output for integration with external plotters and recorders
- Compact module design with removable feet
Physical Specifications
- Dimensions: 159 mm H × 130 mm W × 279 mm D (6.25" × 5.1" × 11")
- Weight: 3.3 kg (7.3 lb) net; 4.5 kg (10 lb) shipping
Compatibility & Integration This is an obsolete product. Operating and service manuals are available for reference.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 Hz to 10 MHz | Power Range (dBm): −72 to +52 dBm | Voltage / Current Range: 1 mV to 300 V (12 ranges) |
Agilent / Keysight 3400A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 3400A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 3400A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Agilent / Keysight 3400A price
This Agilent / Keysight 3400A is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 3400A calibration cost
NIST-traceable calibration for the Agilent / Keysight 3400A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →