HP / Agilent 3457A Digital Multimeter

HP / Agilent Laboratory Measurement Instruments. Voltage: ** 30 mV to 300 V range with 10 nV sensitivity. Ac, Voltage: ** 1 MHz true RMS bandwidth across 30 mV to 300 V..

Model
HP / Agilent 3457A
Calibration
Available on request
Price
$886
Status
In stock
RFQ ref
3457A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3457A is a high-resolution digital multimeter engineered for precision measurement in benchtop and system-integrated environments. It delivers 3½ to 6½ digits of resolution, extendable to 7½ digits, with exceptional DC voltage accuracy of 5 ppm over 90 days. The instrument provides flexible reading rates from 1 reading every 2 seconds to 1350 readings/second at 3½ digits, making it suitable for both slow analog measurements and high-speed data acquisition.

Technical Specifications DC Voltage: 30 mV to 300 V range with 10 nV sensitivity. Accuracy spans 0.0017% + 6 counts at 3 V to 0.005% + 6 counts at 300 V (90-day calibration cycle). Input resistance reaches 10 GΩ on ranges to 3 V, dropping to 10 MΩ ± 1% on higher ranges. AC Voltage: 1 MHz true RMS bandwidth across 30 mV to 300 V. Best accuracy of 0.13% + 0.116 counts from 100 Hz to 20 kHz. Input impedance is 1 MΩ ± 1% with less than 90 pF shunt capacitance. Current Measurement: DC ranges from 300 µA to 1 A with input resistance values 0.1 Ω to 1000 Ω. AC current operates on 30 mA, 300 mA, and 1 A ranges with accuracies of 0.25% + 290 counts and 0.35% + 290 counts respectively. Resistance: 2-wire and 4-wire configurations spanning 30 Ω to 3 GΩ. Best accuracy is 0.0035% + 6 counts at 3 kΩ and 30 kΩ ranges. Sensitivity extends from 10 µΩ to 1 kΩ. Frequency: Voltage input from 10 Hz to 1.5 MHz; current input from 10 Hz to 100 kHz.

Key Features

Storage for over 1000 readings or complete measurement sequences

Non-volatile setup memory for instrument state preservation

Built-in math functions: PASS/FAIL limit testing, NULL, SCALE, and thermistor linearization

Total electronic calibration including AC voltage

HP-IB interface standard

Optional multiplexer assemblies expand capability to ten channels

Typical Applications Precision component characterization, automated test systems, laboratory calibration standards, and long-term monitoring requiring high resolution with drift control.

Compatibility & Integration HP-IB interface enables direct integration into automated measurement systems. Non-volatile memory supports field reconfiguration without external programming.

Specifications

ParameterValue
Frequency Range10 Hz to 1.5 MHz (voltage input)
10 Hz to 100 kHz (current input) | Voltage / Current RangeDCV: 30 mV to 300 V
ACV30 mV to 300 V

HP / Agilent 3457A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3457A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3457A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

HP / Agilent 3457A price

This HP / Agilent 3457A is listed at $885.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3457A calibration cost

NIST-traceable calibration for the HP / Agilent 3457A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents