JDS Uniphase OTDRs. Dynamic range: 34 dB (1310 nm), Accuracy: ±2 dB, Resolution: 0.01 dB.
- Model
- JDS Uniphase 4136LM
- Calibration
- Available on request
- Price
- $1,650
- Status
- In stock
- RFQ ref
- 4136LM
This unit
The JDS Uniphase 4136LM is a Last Mile OTDR module engineered for fiber optic network testing and characterization within the JDSU T-BERD/MTS-4000 platform. Designed for SMF 9/125 µm fiber, it delivers fault location, quick-link testing, and construction-mode trace analysis with fully automatic operation. The module supports in-service testing on PON deployments using ITU-T L41 maintenance wavelengths (1625 nm or 1650 nm), enabling measurements without disrupting active optical traffic.
Technical Specifications Operating Wavelengths and Performance
Central wavelengths: 1310 nm ±20 nm, 1550 nm ±20 nm, 1625 nm ±10 nm, 1650 nm ±20 nm
RMS dynamic range: 34 dB (1310 nm), 32 dB (1550 nm), 32 dB (1625 nm), 30 dB (1650 nm)
Pulse width: 3 ns to 20 µs
Event dead zone: 1 m at 1310 nm (±1.5 dB down from –27 dB reflective event peak)
Attenuation dead zone: 4 m at 1310 nm (±0.5 dB from linear regression using –55 dB reflective event)
Data acquisition: Up to 256,000 points Attenuation and Reflectance Measurements
Attenuation modes: Automatic, manual, 2-point, 5-point, and LSA
Display range: 1.25 to 55 dB
Reflectance accuracy: ±2 dB
Display resolution: 0.01 dB Integrated Loss Test Set (LTS)
Laser source: Continuous wave or modulated operation
Power meter (optional): –2 dBm to –50 dBm range
Power meter wavelengths: 1310 nm, 1490 nm, 1550 nm, 1625 nm, 1650 nm
Power measurement accuracy: ±0.5 dB
Filtered wavelength rejection: 1310 nm, 1490 nm, 1550 nm options available Physical and Safety
Dimensions: 128 × 134 × 40 mm (W × H × D)
Weight: 0.35 kg
Laser safety class: Class 1 (21 CFR)
Key Features
One-button Fault Locator for fiber ends, total loss, and Optical Return Loss (ORL) determination
Quick-link Test mode combining automatic acquisition with detailed trace analysis
Construction Mode for high-level trace analysis during fiber commissioning
In-service testing capability on active PON deployments without traffic interruption
Filtered wavelength options to reject interfering signals on active lines
Typical Applications
Access and premises network construction and commissioning
FTTx deployment and maintenance
Short-haul fiber characterization
In-service PON network testing and troubleshooting
Compatibility & Integration Module for JDSU T-BERD/MTS-4000 Multiple Services Test Platform. Compatible with SMF 9/125 µm fiber.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | –2 dBm to –50 dBm (optional power meter) | Wavelength Range: 1310 nm ±20 nm, 1550 nm ±20 nm, 1625 nm ±10 nm, 1650 nm ±20 nm |
JDS Uniphase 4136LM — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase 4136LM. Calibration covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase 4136LM faults: optical port connector damage or contamination, battery failure, display damage from field use, module failure on FTB or MTS platforms, calibration drift. Most field OTDRs fail due to physical damage. On modular platforms (EXFO FTB, Viavi MTS), individual module failures are serviced without replacing the entire mainframe. Optical port cleaning resolves many apparent measurement faults before mechanical repair is needed.
JDS Uniphase 4136LM price
This JDS Uniphase 4136LM is listed at $1,650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase 4136LM calibration cost
NIST-traceable calibration for the JDS Uniphase 4136LM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →