HP / Agilent 4204A OSCILLATOR

The HP/Agilent 4204A is a high-quality oscillator designed for precision signal generation. It delivers stable and accurate sine wave outputs across a broad frequency range. Ideal for testing, calibration, and general-purpose laboratory applications, this oscillator ensures reliable performance and precise control over signal parameters.

Model
HP / Agilent 4204A
Calibration
Available on request
Price
$466
Status
In stock
RFQ ref
4204A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 4204A is a precision sine wave oscillator engineered for laboratory testing, calibration, and system integration where signal accuracy and stability are critical. It delivers stable output across a wide frequency range with exceptional repeatability and minimal drift, making it ideal for demanding B2B measurement and characterization tasks.


Technical Specifications

Frequency Generation

  • Range: 10 Hz to 1 MHz across 4 selectable ranges

  • Accuracy: ±0.2% or ±1 Hz (whichever is greater) at 25°C

  • Repeatability: Better than ±0.01%

  • Digital selection: Up to 36,900 discrete frequencies via four in-line switches plus continuous vernier control

  • Stability: Post-warmup drift <10 PPM/minute; temperature coefficient <100 PPM/°C; line voltage variation <100 PPM per 10% change Output Characteristics

  • Signal: Sine wave

  • Amplitude: 0 to 10 V RMS into 600 Ω (-60 dBm to +22 dBm); 20 V open circuit

  • Source impedance: 600 Ω

  • Distortion: <0.3% (30 Hz to 100 kHz); <1% (10 Hz to 1 MHz)

  • Hum and noise: 600 Ω maintains waveform purity; lower impedances increase distortion

  • Dual voltage operation: 115 V or 230 V (±10% tolerance), 50–60 Hz, 10 W consumption

  • 0.2 A slow-blow fuse (HP 2110-0106) for both voltage settings


Typical Applications Precision signal generation for component characterization, filter testing, analog circuit validation, and metrology standards verification where frequency accuracy and output stability dominate requirements.


Compatibility & Integration Standard output terminals interface with test loads. Optional HP 11004A line matching transformer extends frequency response to 5 kHz–600 kHz range.

Specifications

ParameterValue
Frequency Range10 Hz to 1 MHz | Power Range (dBm): '-60 dBm to +22 dBm | Voltage / Current Range: 0 to 10 V RMS (into 600 Ω)

HP / Agilent 4204A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 4204A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 4204A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

HP / Agilent 4204A price

This HP / Agilent 4204A is listed at $466. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 4204A calibration cost

NIST-traceable calibration for the HP / Agilent 4204A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →