Keithley 502A

The Keithley 502A is a precision voltage calibrator designed for verifying and calibrating voltmeters and other voltage-measuring instruments. It provides stable and accurate DC voltage outputs, ensuring reliable calibration in laboratory and production environments.

Model
Keithley 502A
Calibration
Available on request
Price
$450
Status
In stock
RFQ ref
502A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 502A is a precision analog milliohmmeter engineered for accurate low-resistance measurements across laboratory and field environments. It delivers reliable readings without zero drift or thermal EMF errors, utilizing 13 overlapping ranges with linear scale indication for direct resistance value display. The instrument achieves 10 µΩ sensitivity and ±3% accuracy (±5% on the 1 mΩ range), making it well-suited for resistivity and contact resistance characterization.

Technical Specifications

Resistance Ranges: 13 overlapping ranges

Sensitivity: 10 µΩ

Accuracy: ±3% of full scale (±5% on 1 mΩ range)

Test Current: 10 mA (1 mΩ to 10 mΩ range); down to 600 µA (1 kΩ range)

Power Dissipation: <2 mW

Voltage Across Sample: 360 hours

Design: Analog

Key Features

Zero drift immunity and thermal EMF rejection

Linear scale across multiple overlapping ranges for unambiguous reading

Low test voltage and current to minimize sample heating and potential damage

Extended battery life supporting continuous field deployment

Typical Applications

Contact and bond resistance measurement

Resistivity characterization

Low-resistance verification in electrical assemblies

Compatibility & Integration The 502A operates with battery types RM 401R, RM 42R, 412, and 413. Analog design allows direct integration into manual measurement workflows without external interfaces.

Specifications

ParameterValue
Voltage / Current Range10 mA (1 mΩ to 10 mΩ range)

Keithley 502A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 502A. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 502A faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.

Keithley 502A price

This Keithley 502A is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 502A calibration cost

NIST-traceable calibration for the Keithley 502A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents