Ametek / EG&G / Princeton Applied Research 5210 Dual Phase Lock-In Amplifier

The Ametek/EG&G/Princeton Applied Research 5210 Dual Phase Lock-In Amplifier is a precision instrument used for recovering signals buried in noise. It measures the amplitude and phase of a signal relative to a reference signal, making it ideal for applications such as optical measurements, materials research, and sensor characterization. This amplifier offers dual-phase operation, enabling simultaneous measurement of in-phase and quadrature components.

Model
Ametek / EG&G / Princeton Applied Research 5210
Calibration
Available on request
Price · starting from
$3,200
Status
In stock
RFQ ref
5210
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ametek/EG&G/Princeton Applied Research 5210 is a dual phase lock-in amplifier designed for precision measurement and recovery of low-level signals in high-noise environments. It simultaneously measures in-phase (X) and quadrature (Y) signal components across a 0.5 Hz to 120 kHz bandwidth, providing both Cartesian (X-Y) and polar (R-θ) output formats. The instrument achieves 130 dB dynamic reserve through Walsh Function Demodulators, ensuring excellent linearity and stability across demanding applications.


Technical Specifications



  • Frequency Range: 0.5 Hz to 120 kHz

  • Voltage Sensitivity (Full Scale): 100 nV to 3 V rms

  • Current Sensitivity (Full Scale): 10 fA to 30 nA or 10 fA to 3 µA

  • Input Impedance: 100 MΩ (voltage); 25 Ω typical (current)

  • Internal Oscillator: 0.5 Hz to 120 kHz, 1 mV to 2 V rms amplitude

  • Dynamic Reserve: 130 dB

  • Output Display: 3½ digit readout

  • Line Rejection Filters: Selectable for 50/60 Hz and/or 100/120 Hz


Key Features



  • Dual phase demodulator with simultaneous X and Y measurement

  • Walsh Function Demodulators for high linearity and stability

  • Calibrated sensitivity with continuous vernier adjustment

  • Auto vernier control for relative measurements

  • Current preamplifier with dual transimpedance settings for direct photodiode coupling

  • Differential input support (A only or A-B configurations)

  • Overload and reference unlock indicators

  • Manual (Local) or computer (Remote) control capability

  • Front panel indicators disableable for blackout operation

  • Analog demodulator outputs suitable for feedback control and envelope recovery applications


Typical Applications



  • Lock-in detection of weak signals in electronic noise

  • Phase-sensitive measurement in optical and photonic systems

  • Feedback control systems requiring true analog demodulation

  • Carrier envelope modulation recovery

  • Low-level current measurements from photodiodes

  • AC bridge measurements and impedance analysis


Compatibility & Integration The 5210 accepts both voltage and current inputs through selectable front panel configurations. The instrument supports remote control for integration into automated measurement systems.

Specifications

ParameterValue
Frequency Range0.5 Hz to 120 kHz | Voltage / Current Range: 100 nV to 3 V rms (voltage sensitivity)

Ametek / EG&G / Princeton Applied Research 5210 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ametek / EG&G / Princeton Applied Research 5210. Calibration covers full-scale sensitivity accuracy at 1 V and at each decade below the maximum range, time constant accuracy, phase offset and phase noise verification, reference frequency range and accuracy, dynamic reserve verification, and noise floor (V/√Hz) measurement. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ametek / EG&G / Princeton Applied Research 5210 faults: keypad ribbon cable wear (intermittent key response), DSP board failure, reference input circuit failure, trim pot drift on analog models. Stanford Research SR810/830 most common fault is front-panel keypad ribbon cable wear causing intermittent key response. DSP board failure is rare but results in loss of lock and incorrect readings. EG&G 5204/5210 analog demodulator units most commonly develop trim pot drift requiring phase and offset recalibration.

Ametek / EG&G / Princeton Applied Research 5210 price

This Ametek / EG&G / Princeton Applied Research 5210 is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ametek / EG&G / Princeton Applied Research 5210 calibration cost

NIST-traceable calibration for the Ametek / EG&G / Princeton Applied Research 5210 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers full-scale sensitivity accuracy at 1 V and at each decade below the maximum range, time constant accuracy, phase offset and phase noise verification, reference frequency range and accuracy, dynamic reserve verification, and noise floor (V/√Hz) measurement. Turnaround is 1 to 3 business days after receipt. See full calibration details →