Astronics / EADS / Racal 6062B4 4-Channel Analog Output Module
The Astronics 6062B4 is a 4-channel analog output module designed for industrial applications. It provides precise and reliable analog signal generation, suitable for control systems, data acquisition, and automated testing environments. This module ensures high accuracy and stability, making it ideal for demanding industrial environments.
- Model
- Astronics / EADS / Racal 6062B4
- Calibration
- Available on request
- Price
- $1,950
- Status
- In stock
- RFQ ref
- 6062B4
This unit
The Astronics/EADS/Racal 6062B4 is a 4-channel analog output module engineered for precision signal generation in automated testing, industrial control, and waveform synthesis applications. This C-size VXIbus module delivers 16-bit resolution across four independent channels with ±10 V output range and ±50 mA sourcing/sinking capability per channel. It combines deterministic settling performance with flexible triggering architecture, supporting both SCPI messaging and pseudo-register control for microsecond-level response times.
Technical Specifications Output Performance
4 channels, 16-bit resolution (14-bit monotonicity)
Output range: ±10 V
Maximum output current: ±50 mA per channel
Accuracy: ±(0.01% FSR + 1 mV) at 23°C ±2°C
Integral non-linearity: ±0.006% FSR
Differential non-linearity: ±0.006% FSR
Temperature coefficient: ±(0.002% FSR + 0.1 mV)/°C
Settling time: 10 µs to 0.1%, 50 µs to 0.01%
Slew rate: >5 V/µs
Small signal bandwidth: >200 kHz
Ripple voltage: 2 mVrms, 5 mVpk-pk
Output modes: 2-wire or 4-wire Waveform Generation
Built-in waveforms: Sine, Triangle, Sawtooth, Ramp, Square
Sine/Triangle/Sawtooth/Ramp: up to 50 kHz
Square waves: up to 25 kHz
Maximum D/A sample rate: 500 kS/s
Memory per channel: 64 k-points
User-defined waveforms: Two stored in flash ROM via Fourier coefficients
Arbitrary waveforms: loadable from file or test program Control Architecture
Trigger modes: Immediate, Continuous, Burst (1 k to 64 k waveforms)
Independent or synchronous channel triggering in groups of two to four
Independent trigger outputs for inter-channel waveform synthesis
Programming: SCPI messages and pseudo-register control
VXIbus protocol: Word serial
Execution time (Interactive mode): <5 ms per channel
Typical Applications
Automated test systems requiring multi-channel waveform synthesis
Industrial process control with synchronized analog outputs
Complex signal generation for sensor simulation and validation
Arbitrary waveform playback in real-time test environments
Compatibility & Integration C-size, single-slot VXIbus module. Integrates with VXIbus systems via message-based or register-based control with optional high-speed operation.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | Sine/Triangle/Sawtooth/Ramp: up to 50 kHz |
| Square waves | up to 25 kHz | Voltage / Current Range: ±10 V output, ±50 mA per channel |
Astronics / EADS / Racal 6062B4 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 6062B4. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Astronics / EADS / Racal 6062B4 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Astronics / EADS / Racal 6062B4 price
This Astronics / EADS / Racal 6062B4 is listed at $1,950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Astronics / EADS / Racal 6062B4 calibration cost
NIST-traceable calibration for the Astronics / EADS / Racal 6062B4 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →