Agilent / Keysight E1467A 8 x 32 Relay Matrix Switch

The Agilent/Keysight E1467A is an 8x32 Relay Matrix Switch module designed for signal routing and switching applications. It features a high-density matrix configuration with 8 rows and 32 columns, providing a large number of switching points for versatile connectivity. This module is ideal for automated test systems, data acquisition, and general-purpose switching needs where reliable and precise signal routing is crucial.

Model
Agilent / Keysight E1467A
Calibration
Available on request
Price
$2,394
Status
In stock
RFQ ref
E1467A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight E1467A is a C-size, 1-slot VXI relay matrix switch delivering 256 two-wire crosspoints in an 8×32 configuration. Built on latching armature relays and register-based control, this module executes non-blocking signal routing with sub-millisecond switching speed. The E1467A scales through matrix expansion via chaining cables, enabling larger configurations - three units create an 8×96 matrix, and a full 13-slot mainframe supports up to 3072 crosspoints.


QUIC terminal blocks provide field-configurable topology selection.


Technical Specifications



  • Matrix Configuration: 8 rows × 32 columns, 256 two-wire crosspoints

  • Switching Speed: <1 ms

  • Relay Type: Latching armature relays

  • Configuration: Non-blocking

  • Terminal Blocks: QUIC design; topology determined by terminal block selection

  • Module Class: Register-based, C-size, 1-slot VXI Crosstalk (50 Ω system, worst-case paths): Within card:

  • Closed-to-closed: −72 dB (<10 kHz), −51 dB (<100 kHz), −33 dB (<1 MHz)

  • Open row-to-row: −91 dB (<10 kHz), −59 dB (<100 kHz), −43 dB (<1 MHz)

  • Open row-to-column: −85 dB (<10 kHz), −64 dB (<100 kHz), −47 dB (<1 MHz)

  • Open column-to-column: −92 dB (<10 kHz), −71 dB (<100 kHz), −54 dB (<1 MHz) Module-to-module (8×64 configuration):

  • Closed-to-closed: −72 dB (<10 kHz), −51 dB (<100 kHz), −33 dB (<1 MHz)

  • Open row-to-row: −74 dB (<10 kHz), −53 dB (<100 kHz), −38 dB (<1 MHz)

  • Open row-to-column: −92 dB (<10 kHz), −72 dB (<100 kHz), −56 dB (<1 MHz)

  • Open column-to-column: −82 dB (<10 kHz), −64 dB (<100 kHz), −50 dB (<1 MHz)


Key Features



  • Scalable Architecture: Supports expansion to larger matrices via optional chaining cable (e.g., E1466-80002) or expansion terminal blocks (Options 201/211)

  • Compatible Core: Shares switch card topology with E1465A and E1466A models for flexible system integration

  • Multi-Protocol Control: GPIB, RS-232, and VXIplug&play interfaces

  • Software Support: LabVIEW, Agilent VEE, MATLAB, and C/C++

  • Relay State: Relays open at power-up


Typical Applications



  • Automated test systems requiring high-density signal routing

  • Data acquisition and multiplexing

  • General-purpose two-wire switching and matrix expansion


Compatibility & Integration The E1467A integrates into standard VXI mainframes and chains with E1465A and E1466A modules. Matrix expansion degrades crosstalk and bandwidth; worst-case specifications apply to expanded configurations.

Agilent / Keysight E1467A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1467A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight E1467A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Agilent / Keysight E1467A price

This Agilent / Keysight E1467A is listed at $2,393.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight E1467A calibration cost

NIST-traceable calibration for the Agilent / Keysight E1467A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents